Permit Number: T06BU00767
Parcel: 12402047B

Review Status: Completed

Review Details: GRADING

Permit Number - T06BU00767
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2006 JOSE ORTIZ ENGINEERING REVIEW Denied To: Paul Dominguez DATE: May 10, 2006
1051 N. Columbus Blvd FROM: Jose E. Ortiz, PE
Tucson. AZ 85711 Engineering Division


SUBJECT: 1st Street Apartments
Grading Plan T06BU00767 (First Review)
T14S, R14E, Section 07

RESUBMITTAL REQUIRED: Grading Plan, & Site Plan

The Grading Plan (GP) and Site Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:

1. Please include a response letter to the comments along with the corrected copies of the GP.
2. List administrative address/site address on plans.
3. List and cross-reference the site plan.
4. Show details of all surface materials.
5. As stated in the site plan comments a permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
6. The following comment pertains to the access ramps at the entrance to the proposed site. "As per Federal ADA requirements, all wheel chair ramps shall have the Truncated Domes instead of the standard grooves, which are shown on City of Tucson Standard Detail 207. Aside from the Truncated Domes, the wheel chair ramps shall be constructed in accordance with the Standard Detail 207. "
7. 100% of the 10-year flow must be conveyed under the sidewalks. Please provide scuppers under concentrated stormwater flows under the sidewalk. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed.
8. To prevent nuisance ponding from occurring on the adjacent lot water harvesting techniques shall be incorporated into the development by conveying rooftop drainage to designated water harvesting areas. Please address how water-harvesting techniques will be incorporated into the development. Refer to the newly adopted City of Tucson Water Harvesting Guidance Manual for design considerations.



If you have any questions, I can be reached at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov
Jose E. Ortiz, PE
Civil Engineer
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1191 office
(520) 879-8010 fax
04/27/2006 PETER MCLAUGHLIN NPPO REVIEW Denied Approval of site plan and landscape plan required prior to grading plan approval.
05/20/2006 DAVID RIVERA ZONING REVIEW Denied 05/20/06

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/19/2006 CINDY AGUILAR OUT TO CUSTOMER Completed
07/19/2006 SUE REEVES REJECT SHELF Completed