Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T06BU00746
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 09/11/2007 | ANDREW CONNOR | NPPO | REVIEW | Denied | Landscape plan approval is necessary to continue review. |
| 09/12/2007 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: September 13, 2007 SUBJECT: Dory's Apartments TO: Guillermo Andrade LOCATION: 407 W Utah, T15S R13E Sec01 Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: T06BU00746 (Grading Plan) SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised grading plan, Drainage Report (Indevco A & Es, Inc., 20AUG07), and the Geotechnical Engineering Report with addendum (Terracon, project # 63055280) and does not recommend approval of the grading plan at this time. The following items need to be addressed: GRADING PLAN COMMENTS: Please ensure that the Grading Plan is consistent with the Site Plan and Drainage Report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf 1. Revise the grading plan to label and dimension the required 5-foot sidewalk width, in plan view, for the proposed sidewalk along the frontage of Utah Street. Also revise Section A-A to show the 5-foot dimension for this proposed sidewalk. 2. Clarify the use of the 2 inlets for the proposed detention basin. The drainage report and site plan only show (1)-4.5-foot curb opening along the access PAAL for the inlet to the detention basin. The grading plan shows (2)-4.5-foot curb openings, clarify. 3. Revise Section A-A on the grading plan sheet to label all dimensions for construction purposes. The proposed sidewalks must be dimensioned and the concrete toe-down for the sidewalk adjacent to the building must clearly dimension the toe-down depth or have a note to reference Section C-C for the toe-down depth along the entire length of the propsoed sidewalk. 4. Review and approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Refer to the following links for TDOT Forms and applications: a) http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/applications.html / b) http://www.dot.ci.tucson.az.us/engineering/pia.php c) Or contact Steve Tineo at 741-3115 for all additional questions regarding r-o-w. 5. Be advised that further comments may be forth coming on resubmittal of the site plan. GENERAL COMMENTS: Please provide a revised grading plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package. Further comments may be generated upon resubmittal of the grading plan review. If you have any questions, or to schedule an appointment, I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/25/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 09/25/2007 | CINDY AGUILAR | REJECT SHELF | Completed |