Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06BU00405
Parcel: Unknown

Review Status: Completed

Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG

Permit Number - T06BU00405
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2006 EGRANT1 ZONING REVIEW Needs Review
04/11/2006 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied .. T06BU00405 .. 5802 E FORT LOWELL ROAD .. DGL .. FIRST REVIEW COMMENTS ..
.. #1 THROUGH #19 .. 4/11/06 ..

S1. Provide completed Commercial Plan Review Checklist, see website www.tucsonaz.gov/dsd forms.
S2. Provide completed Code Review Checklist, see website www.tucsonaz.gov/dsd forms.
S3. Provide architectural site showing and annotating project property lines, locating new structure dimensionally from two adjacent property lines and from existing structure/s, identify existing and new structures on site by occupancy and type of construction, show existing or new fire walls including fire-rating, location and reason for firewall/s.
S4. This structure is not a U Occupancy, so reclassify based on function, per 2003 IBC.
S5. Resolve / clarify prior two permits :
1. T02EL01662 EXPIRED.
2. T05EX01169 ISSUED.
S6. Explain permitting of Existing Building, provide copy of permit for this building, prior to issuance of this permit.
S7. State USE/ OCCUPANCY of shade structure on drawings.
S8. State TYPE OF CONSTRUCTION of the shade structure on the drawings.
S9. State OCCUPANT LOAD on drawings.
S10. State CODES used on drawings.
S11. Address accessibility requirements on drawings.
S12. Provide adequate spot elevations to show accessibility.
S13. Provide architectural details and specifications for the roof.
S14. Architect verify Parcel number and address of site and coordinate on drawings and documentation.
S15. Provide address on canopy per Pima County Addressing Ordinance and per IBC Section 501.2.
S16. Clarify bottom of footing 18" minimum below existing grade on drawings vs 12" noted on S 0.1, per structural calculations and IBC Section 1805.2 as amended.
S17. Provide connection detail/s for blocking to joists.
S18. Since uplift loads are often critical with canopies, show full compliance with IBC Section 1609, including treatment of metal roof as both component and cladding and documentation of dead loads, as well as addressing proximity of canopy to adjacent existing building, classify canopy as open, enclosed or partially enclosed per Section 1609 and ASCE 7,Section 6.
S19. Special Inspection is required per drawing S0.1and 1997 UAC Section 306 for :
1. Soils.
2. High Strength Bolting
3. Field Welding.


Questions? Call Douglas Laakso, Structural Plans Examiner COT- DSD,
at (520) 791-5550 x 1111.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/13/2006 AMERY KLAPPERT OUT TO CUSTOMER Completed
04/13/2006 SUE REEVES REJECT SHELF Completed