Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T06BU00249
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan approval is necessary to continue review. |
| 07/31/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | To: Paul Nzomo DATE: August 1, 2006 Coronado Engineering & Delvelopment, Inc. 1010 N. Finance Center Drive, Ste. 200 Tucson, Arizona 85705 SUBJECT: Pantano Homes, 2491 S. Pantano Pw Grading plan T06BU00249 (Second Review) T14S, R15E, Section 21 RESUBMITTAL REQUIRED: Grading Plan, Drainage Report and SWPPP. The Grading Plan (GP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP. 2. Show the 100-year flood peak discharge. 3. Slopes of 3H: 1V require hand placed riprap or re-vegetation at a minimum. Show rip-rap on the x-sections of the basins along with mirafi filter fabric and the WSEL's. 4. Contact Permits and Codes at (520) 791-5100 for permission for placement of the rock rip-rap splash pads located within the Right-of-way. 5. Call out peak discharges entering and exiting the site. Drainage Report: 1. Please include a response letter to the comments along with the corrected copies of the DR. 2. Show rip-rap on the x-sections of the basins along with mirafi filter fabric and the WSEL's. 3. Include the percolation test results with the next submittal. Grading plan approval will not be given until percolation tests results have been submitted and accepted. 4. Show the project address or administration address on the cover sheet of the DR. 5. Contact Permits and Codes at (520) 791-5100 for permission for placement of the rock rip-rap splash pads located within the Right-of-way. Stormwater pollution prevention plan: 1. The SWPPP has been accepted by engineering, however, please re-submit the 4 SWPPP binders along with the SP and DR corrections. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/2491 S. Pantano PW Grad2 |
| 07/31/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | Approved conditionally upon the completion of the site comments. |
| 09/08/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: PANTANO MULTI-FAMILY HOMES T06BU00249 Grading Plan TRANSMITTAL DATE: September 12, 2006 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\grading\t06bu00249.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/25/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 09/25/2006 | SUE REEVES | REJECT SHELF | Completed |