Review Details: REVISION - GRADING

Permit Number - T06BU00190
Review Name: REVISION - GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: January 30, 2007
TO: Allied Homes c/o Pete Salonga, PE
SUBJECT: Montage Vista II Lot 71 resubmittal Revised Grading Review
LOCATION: 3172 W Salvia Drive
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBERS: T06BU00190-R

SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised grading plan for lot 71 and recommends approval of the grading plan with the following conditions to the permit.

REVISED GRADING PERMIT 9 CONDITIONS:
1) This revision T06BU00190-R includes the grading of the frontage slope between the driveway and wash.
2) Fill area between driveway and wash shall have permanent erosion protection, in the form of established vegetation and/or rock.
3) Any exposed areas, between interceptor swale and driveway or other rocked area, shall have grouted rip rap or rip rap with filter fabric.
4) Wash rip rap slope shall not exceed 3:1(H:V) as per plan.
5) There shall be no disturbance or stockpiling outside of the approved Grading Limits as shown on the Grading Plan.
6) No further disturbance of the wash will be allowed, other than that shown on the approved grading plan.
7) Minimum 2' setback from property line to grading limits shall be maintained.
8) Temporary erosion control devices shall be placed as needed at downstream side of grading limits.
9) No stockpiling in the wash.

If you have any questions, I can be reached at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
02/01/2007 ANDREW CONNOR NPPO REVIEW Approved
02/01/2007 MICHAEL ST. PAUL ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/01/2007 GERARDO BONILLA OUT TO CUSTOMER Completed