Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06BU00133
Parcel: Unknown

Address:
4050 E BENSON HY

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T06BU00133
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/09/2006 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: February 9, 2006
SUBJECT: Cantera S05-030 Stockpile Grading Plan resubmittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: T06BU00133
LOCATION: T15S R14E Section 10

SUMMARY: The revised Stockpile Grading Plan, revised SWPPP documents, a copy of the Tentative Plat, were received at the counter by Engineering on February 8 and 9, 2006, and added to the package with the other Landscaping documents. Engineering Division has reviewed the received items and recommends approval of the Stockpile Grading Plan. The following conditions will apply to the permit:

GRADING PLAN CONDITIONS:
THERE SHALL BE NO ENCROACHMENT OF INTO THE JURISDICTIONAL FLOODPLAIN AS INDICATED ON THE PLAN.
ANY GRADING OUTSIDE OF THE GRADING LIMITS SHALL REQUIRE SUBMITTAL, REVIEW, AND APPROVAL FOR A SEPARATE PERMIT.
ANY REVISION TO THE GRADING PLAN MAY REQUIRE A RE-SUBMITTAL OF THE REVISED GRADING PLAN FOR REVIEW. CONTACT DSD ENGINEERING AT 791-5550 TO DISCUSS CHANGES IN GRADING DESIGN.
IF THE FILL IS PLACED WITHIN 100 FEET OF RESIDENTIALLY ZONED PARCELS, DIFFERENTIAL GRADING PROCEDURES WILL NEED TO BE FOLLOWED PER DS SEC.11-01.8.1.A.1-4.
BOND SHALL REMAIN IN PLACE FOR STOCKPILE GRADING AND RESEEDING UNTIL FURTHER NOTICE OR UNTILL THE FINAL GRADING PERMIT IS ISSUED FOR THE PROJECT DEVELOPMENT GRADING CONSTRUCTION.
CONTACT PERMITS AND CODES (791-5100) FOR ANY QUESTIONS REGARDING RIGHT-OF-WAY PERMIT REQUIREMENTS.
THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) SHALL HAVE SIGNATURES FOR ANY NEW OPERATORS ON SWPPP AT THE SITE.
CALL FOR INITIAL SWPPP INSPECTION AS WELL AS A STOCKPILE GRADING PRE-CONSTRUCTION MEETING. FOR A DSD ENGINEERING INSPECTIONS, CALL IVR (740-6970), OR SCHEDULE WITH A CUSTOMER SERVICE REPRESENTATIVE AT THE DEVELOPMENT SERVICES DEPARTMENT, OR SCHEDULE INSPECTIONS ONLINE AT: HTTP://WWW.CI.TUCSON.AZ.US/DSD/ONLINE_SERVICES/ONLINE_PERMITS/ONLINE_PERMITS.HTML OR CONTACT DSD ENGINEERING AT 791-5550 EXTENSION 2101.

If there are any questions, you may contact me at 791-5550 ext.2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
02/10/2006 DAVID RIVERA ZONING REVIEW Approved
02/10/2006 ANDREW CONNOR NPPO REVIEW Approved