Plan Review Detail
Review Status: Completed
Review Details: PIA SUBMITTAL
Plan Number - T05PI00004
Review Name: PIA SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2005 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | March 22, 2005 PIA – Landscape Review By Gary Wittwer T05PI00004 Wilmot Road - MMLA Comments: Please address Native Plant Preservation Ordinance. |
| 03/24/2005 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | Sheet 1: Add Streets signature block |
| 03/28/2005 | THAD HARVISON | DOT ENGINEERING | REVIEW | Denied | DATE: March 23, 2005 TO: PIA Coordinator FROM: Richard Leigh, EA Development Services Department Permits & Code Section Department Of Transportation SUBJECT: Wilmot Road at Desert Stone Paving plan plan T05PI00004 (First Review) T 15 S, R 15E, Section 19 RESUBMITTAL REQUIRED: Paving Plan The Paving Plans cannot be approved as submitted. Please have the following review comments addressed prior to the next submittal. Paving Plan: 1. Remove signature lines for Pima County Waste Water, City of Tucson, Parks and Recreation and Tucson Water from the cover sheet. 2. Revise title block to reflect attached sample title block. 3. All strip paving will requires a thickened edge treatment, see attached detail. 4. Any proposed sidewalk along a roadway listed on the "City of Tucson Major Streets and Roadway" needs to be a minimum of six (6) foot wide. 5. Provide a tapered pavement section treatment starting at Sta. 47+33.03. 29.23' LT (Wilmot Road) and 68+00, 11.00' LT (Wilmot Road), see attached detail. 6. Provide a curb terminal section per PC/COT Sta. Dtl. 212 at all curb terminations. 7. Label the proposed curb access ramp at Sta. ± 51+20, 50.00' LT. 8. Provide a complete detail of the proposed sidewalk scupper at Sta. 57+54.76, 39.00' LT on plan set. 9. Provide complete details of the proposed box culvert across Wilmot Road on plan set. 10. Provide a survey monument per PC/COT Sta. Dtl. 103 at the intersections of all public streets within the limits of the proposed new pavement section. 11. Submit an approved drainage report for the proposed improvements in the public right-of-way with subsequent submittal. 12. Submit approved tentative for the associated development with subsequent submittal. 13. Add administrative address on cover sheet. 14. Add developer and or owners information on cover sheet. 15. Provide a legend for the symbols, hatching and lines used on cover sheet. 16. Resubmit paving plans only when plans are 100% complete and sealed by engineer-of-record. 17. Please add the following notes to the General/Paving Notes of the Paving Plans: a. The City shall not be held liable for any errors and/or omissions on these plans. Items not meeting City Standards shall be repaired/replaced at no cost to the City. b. All Drainage infrastructures, indicated on the plans, are in accordance to the approved Drainage Report approved by Development Services Department. c. The Engineer of Record shall submit to the City for acceptance any changes to the approved plans prior to construction. Additionally, the Engineer of Record shall certify all changes meeting all applicable standards, codes, and ordinances. d. A Floodplain Use Permit No. has been issued by Development Services Department for work impacting City and FEMA Floodplains. If you have any questions, I can be reached at (520) 792-2593 or Rleigh1@tucsonaz.gov. Richard Leigh Engineering Associate DOT, Engineering, Permits & Code Unit 201 N. Stone Ave, 4th Floor Tucson AZ, 85701 520-791-5100 Rleigh1@tucsonaz.gov |
| 03/28/2005 | THAD HARVISON | DOT ENGINEERING | REVIEW | Denied | Utility Awareness Notification not received from EOR |
| 03/28/2005 | THAD HARVISON | DOT ENGINEERING | UTILITY AWARENESS NOTIFICATION | Denied | DATE: March 23, 2005 TO: PIA Coordinator FROM: Richard Leigh, EA Development Services Department Permits & Code Section Department Of Transportation SUBJECT: Wilmot Road at Desert Stone Paving plan plan T05PI00004 (First Review) T 15 S, R 15E, Section 19 RESUBMITTAL REQUIRED: Paving Plan The Paving Plans cannot be approved as submitted. Please have the following review comments addressed prior to the next submittal. Paving Plan: 1. Remove signature lines for Pima County Waste Water, City of Tucson, Parks and Recreation and Tucson Water from the cover sheet. 2. Revise title block to reflect attached sample title block. 3. All strip paving will requires a thickened edge treatment, see attached detail. 4. Any proposed sidewalk along a roadway listed on the "City of Tucson Major Streets and Roadway" needs to be a minimum of six (6) foot wide. 5. Provide a tapered pavement section treatment starting at Sta. 47+33.03. 29.23' LT (Wilmot Road) and 68+00, 11.00' LT (Wilmot Road), see attached detail. 6. Provide a curb terminal section per PC/COT Sta. Dtl. 212 at all curb terminations. 7. Label the proposed curb access ramp at Sta. ± 51+20, 50.00' LT. 8. Provide a complete detail of the proposed sidewalk scupper at Sta. 57+54.76, 39.00' LT on plan set. 9. Provide complete details of the proposed box culvert across Wilmot Road on plan set. 10. Provide a survey monument per PC/COT Sta. Dtl. 103 at the intersections of all public streets within the limits of the proposed new pavement section. 11. Submit an approved drainage report for the proposed improvements in the public right-of-way with subsequent submittal. 12. Submit approved tentative for the associated development with subsequent submittal. 13. Add administrative address on cover sheet. 14. Add developer and or owners information on cover sheet. 15. Provide a legend for the symbols, hatching and lines used on cover sheet. 16. Resubmit paving plans only when plans are 100% complete and sealed by engineer-of-record. 17. Please add the following notes to the General/Paving Notes of the Paving Plans: a. The City shall not be held liable for any errors and/or omissions on these plans. Items not meeting City Standards shall be repaired/replaced at no cost to the City. b. All Drainage infrastructures, indicated on the plans, are in accordance to the approved Drainage Report approved by Development Services Department. c. The Engineer of Record shall submit to the City for acceptance any changes to the approved plans prior to construction. Additionally, the Engineer of Record shall certify all changes meeting all applicable standards, codes, and ordinances. d. A Floodplain Use Permit No. has been issued by Development Services Department for work impacting City and FEMA Floodplains. If you have any questions, I can be reached at (520) 792-2593 or Rleigh1@tucsonaz.gov. Richard Leigh Engineering Associate DOT, Engineering, Permits & Code Unit 201 N. Stone Ave, 4th Floor Tucson AZ, 85701 520-791-5100 Rleigh1@tucsonaz.gov |
| 03/28/2005 | THAD HARVISON | DOT ENGINEERING | UTILITY AWARENESS NOTIFICATION | Denied | Utility Awareness Notification not received from EOR |
| 04/21/2005 | DALE KELCH | DOT TRAFFIC | REVIEW | Denied | No comments provided. |
| 04/29/2005 | MATT FLICK | ENGINEERING | REVIEW | Needs Review | Plans distributed to review agencies. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/02/2005 | TAMI ACHONG | OUT TO CUSTOMER | Completed |