Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T05PI00002
Review Name: PIA RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2006 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approv-Cond | We have reviewed these plans and have the following comments: Landscape: 1. Main line filter and flush valve filter need schedule 80 unions. 2. Need senninger preset regulators. No further comments 3/31/06 |
| 04/03/2006 | Estevan Tineo | DOT ENGINEERING | REVIEW | Denied | 4/3/2006 - Menlo Park Mercado District (T05PI00002) Please note the following comments (at a minimum) that must be addressed in the next submittal: 1. Previous comment 8 not addressed "Sheet 2 of 8: Provide vertical curves for longitudinal changes in grade greater than 1%." This comment must be addressed. The proposed horizontal and vertical alingment must follow the ASSHTO Green Book design guidelines, revise accordingly. 2. Previous comment 6 not addressed "General comment: Detail on plans each type of ramps to be used, include truncated domes per Federal Standards." Detail each type of ramp on plans. |
| 04/07/2006 | TAMI HAUSER | ENGINEERING | REVIEW | Needs Review | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 04/07/2006 | TAMI HAUSER | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 04/13/2006 | TAMI HAUSER | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 04/13/2006 | DALE KELCH | DOT TRAFFIC | REVIEW | Denied | Traffic Engineering REJECTS this PIA submittal: 1. Sheet 3/8: At the SWC of Avenida Convento/Congress is a sign facing eastbound traffic on Congress that is called out as keynote 26. I believe this should be keynote 27. 2. Sheet 3/8: there are several keynote 22 callouts on this sheet with no keynote 22 identified in the legend. Striping plan: 1. General note 4: The title of the referenced manual is "The Manual ON Uniform..." not of. 2. Sheet 2/2: Identify the R1-1 and R3-5(R) signs. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 04/13/2006 | TAMI HAUSER | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 04/13/2006 | THAUSER1 | CONSTRUCTION ESTIMATE | REVIEW | Needs Review |