Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T05OT02849
Parcel: 107113410

Review Status: Active

Review Details: FLOODPLAIN

Permit Number - T05OT02849
Review Name: FLOODPLAIN
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
11/29/2005 SUZANNE BOHNET ENGINEERING REVIEW Approved 11/30/05

FLOODPLAIN USE PERMIT NO. T05OT02849
ADDRESS: 169 E. Placita Estrella
APPLICANT: Tom Weninger
The applicant is authorized to use a portion of the City of Tucson property described as (legal description): Estrella Heights Lot 2

1. This permit is for the purpose of a Manufactured Home installation within a City of Tucson Flood Hazard area.

2. The proposed structure is impacted by the regulatory floodplain. For purposes of this permit, the following elevation requirements apply:

Base Flood Elevation (BFE) = 2337.2 feet per the National Geodetic Vertical Datum (NGVD '29)
Regulatory Flood Elevation (RFE) = 2338.2 feet per the National Geodetic Vertical Datum (NGVD '29)

The bottom structural member and all attached equipment of the manufactured home must be elevated to the Regulatory Flood Elevation (RFE). All service utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), must be elevated to the Regulatory Flood Elevation (RFE). An Elevation Certificate completed and certified by an Arizona Registered Land Surveyor or Arizona Registered Professional Civil Engineer must be returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue prior to the electrical inspection.

3. Any additional improvements, including block walls, fences or pools, will require a separate Floodplain Use Permit prior to construction.