Permit Number: T05OT02633
Parcel: 138213640

Address:
131 W ELVIRA RD

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T05OT02633
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2005 ELIZABETH EBERBACH ENGINEERING REVIEW Approved see FPUP:

===
October 31, 2005
FLOODPLAIN USE PERMIT # T05OT02633
PROJECT ADDRESS: 131 West Elvira Road
APPLICANT'S NAME: Bill Watkins
PROPERTY OWNER: Matt Lottman, 334 South 6th Avenue, Tucson, 85701

This parcel lies in a local City of Tucson floodplain. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

A 4.6 acre project at Book 58 page 43 in a portion of Ward 1, located at the southwest corner of South Missiondale Road and West Elvira Road, in Tucson, AZ 85706, , in a portion of Township 15 South, Range 13 East, Section 13,

for the purpose of grading construction and residential improvements for Desert Vista subdivision.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 11 conditions apply to this permit:
1) Although the project is located in FEMA X unshaded Zone (FEMA X Unshaded Zone map numbers 040076 C 2238/2239/2830 K), there is a local flood hazard area within the project site and the east and south areas of the project.
2) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the structure and / or site development, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
3) This permit is issued for grading construction and drainage improvements only for Desert Vista (S03-014) as shown on the approved plans. All work shall conform to the approved GRADING PLAN FOR DESERT VISTA SUBDIVISION (activity number T04BU00122), by A.C.Tsang Engineering, Inc. (sealed 12/18/03, approved 9/20/04), and any associated geotechnical engineering and drainage reports, which are made part of this permit.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T05OT02633 FOR INFORMATION PLEASE CALL 791-5550."
5) Copies of the Floodplain Use Permit and Grading Permit with the approved plans shall be kept in a readily accessible location on site at all times.
6) Any additional future improvements in the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. Any future walls or other structures located in or near the drainage areas shall have separate floodplain use permit applications submitted to this office for review and approval.
7) It will be necessary to call for SWPPP inspections, final floodplain use permit inspections, and subsequent reseed bond inspection by Development Services Department Engineering Division Inspection Team.
8) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
9) Construction entrance only from approved location(s) as indicated on the grading plan.
10) There shall be no stockpiling earthen or other material, or storage of vehicles, within the basin area.
11) There shall be no disturbance outside of grading limits.
12) Additional Floodplain Use Permits with elevation certificates will be required for lots 1 through 10 and lots 27 through 31, prior to issuance of individual lot building permits.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire two years from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 10 Day: 27 Year: 2007

APPLICANT: Bill Watkins
ADDRESS: 9289 North Hampshire Drive, Tucson 85742
PHONE: (520) 850-0517
CONTRACTOR: 4-Hire Contracting
ADDRESS: 6944 North Camino Martin, Suite 130, Tucson, Arizona 85741
PHONE: (520) 744-8068
===

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2005 GBONILL1 OUT TO CUSTOMER Completed