Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05OT01774
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2005 | JIM EGAN | FIRE | REVIEW | Denied | 1. Remove fencing from cul-de-sac turnaround. 2. Show location of existing fire hydrant on plan. |
| 08/31/2005 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/31/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Landscaping is required along retention basin side slopes, bottom and periphery. Plant materials used in basins shall withstand periodic inundation. A minimum of 20 trees per acre must be provided, 33% of tress shall be 24" box or larger (indicate the size of trees within basin). A minimum of 2 shrubs for each tree is required (indicate the type and size of shrubs) per DS 10.01. 2. Include planting plan, which indicates the, sizes, and name of each type of vegetation per DS 2-07.2.2.A.1.e |
| 09/14/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. List the existing building height. (D.S. 2-02.2.1.A.6) 2. Fully dimension all standard and disable parking spaces. Indicate the disabled parking space and access aisle on the plan. (D.S. 2-02.2.1.A.8) 3. Provide a fully dimensioned detail of the disabled parking space, access aisle, and ramp. (D.S. 2-02.2.1.A.8) (ICC/ANSI A117.1-2003) 4. Provide the vehicle parking calculation. The calculation shall include the land use class, ratio used, and number of vehicle parking spaces required and provided. Refer to LUC Sec. 3.3.4 for parking requirements. (D.S. 2-02.2.1.A.8) (D.S. 2-02.2.2.A.4) 5. Provide the bicycle parking calculation. The calculation shall include the class type and number of bicycle parking spaces required and provided. Refer to LUC Sec. 3.3.4 for parking requirements. (D.S. 2-02.2.1.A.8) (D.S. 2-02.2.2.A.4) 6. If new bicycle parking is proposed, provide a fully dimensioned detail of the facility. Indicate the location of the facility and the number and class type provided at that location. Refer to D.S. 2-09 for design criteria. (D.S. 2-02.2.1.A.9) 7. Label and dimension existing and future sight visibility triangles. (D.S. 2-02.2.1.A.10) 8. Dimension the width of all PAALs located on-site. In addition, indicate the direction (one-way or two-way) for the PAALs located in the outdoor storage area on the drawing. If they are one-way show how the storage area will be parked (angle?) to demonstrate maneuverability requirements. (D.S. 2-02.2.1.A.11) (D.S. 2-02.2.1.A.12) 9. On-site accessible pedestrian path is required from the building to the accessible parking spaces and to the sidewalk located in the Wilmot Road right-of-way. See D.S. 2-08 for location and specification requirements. (D.S. 2-02.2.2.1.A.12) 10. If applicable, provide a detail of existing and or proposed free standing signage, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.2.1.A.13) 11. If applicable, all existing and proposed easements must be shown on the plan including width, type, whether they are public or private, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 12. Indicate the location of the refuse container. (D.S. 2-02.2.1.A.32) 13. Label and dimension existing loading zones. As a note, list the number and size of the existing loading spaces. If new loading zones are proposed, label and dimension. (D.S. 2-02.2.1.A.14) (D.S. 2-02.2.2.A.5) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
| 09/14/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Denied | See Zoning Review comments. |
| 09/21/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To:Architecto E.J. Ornelas,Assoc,DATE: September 21, 2005 Edward Ornelas 100 N. Stone Ave. Ste. 1002 Tucson, Arizona 85701 SUBJECT: American Self-Storage, 2501 S. Wilmot Road Site plan T05OT01774 (First Review) T14S, R15E, Section 19 RESUBMITTAL REQUIRED: Site Plan and Hydrology Report. The Site Plan (SP) and Hydrology Report (HP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 3. Please provide property description per D.S. 2-02.2.1.3. 4. There is a descripency between the key note 8 and the utility symbols. 5. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 6. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 7. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 8. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 9. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 10. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 11. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 12. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 13. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. The easement called out on note 8 is not shown on the plat of Tierra Del Sol, Bk. 13, Pg. 16. Revise as required. 14. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP. 15. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 16. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 17. Show Site plan number (T05OT01774) on all sheets per D.S. 2-02.2.1.29. 18. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 19. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 20. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP 21. List the consulting engineer and the owner/developer on the plans with the pertinent information. 22. "A Stormwater Pollution Prevention Plan (SWPPP's) will be required for this project. Submit 3 sets of the grading and SWPPP with text upon completion of the revisions. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans". Hydrology Report: 1. Please include a response letter to the comments along with the corrected copies of the HR. 2. Percolation tests are required prior to the issurance of any permits. 3. The Hydrology Report is conditionally accepted for Site plan purposes only. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/2501 S. Wilmot Rd Site |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/26/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |