Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05OT01150
Parcel: 20914001C

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T05OT01150
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/05/2005 BLANCA ESPINO ENGINEERING REVIEW Approved May 5, 2005

FLOODPLAIN USE PERMIT NO. T05OT01150
ADDRESS: 6400 S. Aviator Lane
PROPERTY OWNER: City of Tucson

The applicant is authorized to use a portion of the City of Tucson the property described as (legal description): Ryan's Airfield. ALL EXC SE TRI PTN & EXC AJO RD & EXC WELLSITE 610.66' AC SEC 12-15-11

1. This permit is for the purpose of setting a manufactured building within a FEMA floodplain, Zone AO 1'.

2. The proposed building is impacted by the regulatory floodplain. The building must be elevated above the floodplain 100-year WSE. This can be achieved by either building up the building pad to the 100-year WSE or higher, or elevating the building by any other acceptable method such as stem walls, piers, etc, depending on what the drainage report, the engineer or the owner is proposing. The building lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2-feet above existing grading, NGVD 1929 as certified by a Registered Land Surveyor.

NOTICE
This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy.