Permit Number: T05OT01110
Parcel: 11519034A

Address:
1805 W GRANT RD

Review Status: Completed

Review Details: SITE

Permit Number - T05OT01110
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/25/2005 JIM EGAN FIRE REVIEW Approved
06/07/2005 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens FOR: David Rivera
Senior Planner Principal Planner

PROJECT:T05OT01110 & T05CM01946
1805 W. Grant Rd.
Storage Yard/Light Poles

Transmittal date: 1st Review 6/13/05

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please indicate clearly what type of equipment is going to be stored on this site. I am unable to determine the use group proposed for the property based on the information provided. The following review comments are based upon a commercial storage use.

2. The electrical plan indicates power for the light poles is being provided from the property to the west. This site must be considered a stand alone property or the increase in lot area will cause the entire property to the west to be brought up to full code compliance as well.

3. Clearly indicate that there is no access from the proposed site to the property to the west.

4. As per DS 2-02.2.1.6 Indicate the area to be used for the commercial storage along with the square footage of the storage area.

5. As per DS 2-02.2.1.7. Indicate the required and proposed zoning setbacks.

6. As per DS 2-02.2.1.8. Indicate the required off street parking, including fully dimensioned layout, location, parking spaces, size and number, and typical parking space details for both handicapped and standard spaces, together with access thereto.

7. As per DS 2-02.2.1.9 Off-street bicycle parking, including materials for lighting, paving, and
security; fully dimensioned layout; location; specific type of rack and the
number of bicycles it supports; and the location and type of directional
signage.

8. As per DS 2-02.2.1.10 Existing and future sight visibility triangles.

9. As per DS 2-02.2.1.11 Points of egress and ingress including locations and width of driveways
and parking area access lanes (PAALs).

10. As per DS 2-02.2.1.12 Vehicular, bicycle, pedestrian, and handicapped circulation clearly
identified.

11. As per DS 2-02.2.1.13 Location, type, size, and height of existing and proposed signage. If applies.

12. As per DS 2-02.2.1. 14 Fully-dimensioned loading space(s) and maneuvering area(s).

13. As per DS 2-02.2.1. 21 Dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines.

14. As per DS 2-02.2.2.A. The following calculations are required on the site plan, including the methodology. If there is not enough space on the site plan to include these calculations, another plan sheet is used.
1. Gross and net lot area.
2. Floor area for each building.
3. Percentage and area in square feet of building and accessory building
coverage.
4. Vehicular and bicycle parking spaces required and provided, including
handicapped.
5. Number of loading spaces required and provided.
6. Percentage of building or lot area expansion. If the building(s) or lot area
have been previously expanded, those calculations shall be included.

15. As per a discussion with Wayne Bogdan of Zoning Enforcement this project will require an interpretation from the Zoning Administrator as to whether it is an expansion of the property to the west or a stand alone use, as well as, if it is a stand alone use will a building be required. Please submit a letter along with plans to the Zoning Administrator for his interpretation. The next resubmittal must include a copy of the letter with the Zoning Administrator's determination.

16. Depending on what is resubmitted and what the Zoning Administrator's determination is, further comments may be forth coming.



If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5608 ext. 2000.
06/09/2005 TERRY STEVENS ZONING HC SITE REVIEW Approved
06/14/2005 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. On sites where the gross floor area of the existing building(s) is more than ten thousand (10,000) square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:

· If the expansion is less than 25%, the requirements of this Division apply only to the proposed expansion. Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval per LUC 3.7.1.2.B

· If the expansion is 25% or greater or if expansions as of February 15, 1991 cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the requirements of this Division apply to the entire site per LUC 3.7.1.2.B

2. A 6' screen is required to screen Grant Rd. from storage area per LUC 3.7.2-I. (2) years will be used as a base for shrub growth calculation.

3. Vegetative screens can encroach three (3) feet into the street landscape border. If the growing characteristics of selected plant material, at maturity, are of a width greater than three (3) feet, the plant location will be moved farther away from the street property line to allow for the growth per DS 2-06.3.7.B.5.b

4. All disturbed grubbed, graded, or bladed areas not otherwise improved shall be landscaped, re-seeded, or treated with an inorganic or organic ground cover to help reduce dust pollution. Provide treatment for unpaved areas to the east and south of storage facility.

5. Provide a NPPO plan or application for exception per DS 2-15.0

6. Additional comments may apply per resolution of Zoning comments #'s 15 and 16.
06/14/2005 ANDREW CONNOR NPPO REVIEW Denied Provide a NPPO plan or application for exception per DS 2-15.0
06/22/2005 LOREN MAKUS ENGINEERING REVIEW Denied 1. This project is in a balanced basin. Provide a drainage report showing how detention requirements will be met. (Retention/Detention Manual
2. Since the parcel was created after September 4, 1984, 5-year threshold retention is required. Show how these requirements will be met. (Drainage Manual 14.2.1)
3. Show location of entry driveways on adjacent properties. Driveways must be at least 80 feet apart with no more than two driveways within 300 feet.
4. Revise the driveway to provide curb returns and access ramps. The curb returns must be a 25 foot radius. (Access Management Guidelines 5.5)
5. Expain how the site will be graded to the slopes indicated with no fill. Revise the cut and fill quantities as necessary.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/28/2005 JMORALE1 OUT TO CUSTOMER Completed
06/28/2005 SUE REEVES REJECT SHELF Completed