Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05OT00852
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/26/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. Indicate contour intervals along with the north arrow and scale. This should be placed together. D.S. 2-02.2.1.A.1 3. Submit a copy of the Lot combination recorded document. 4. Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Add note, "All roof spouts will be routed under any adjacent sidewalk." D.S. 2-08.3.1 & 4.1.E 5. Within all development, a continuous pedestrian circulation path is required. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets cannot be placed across the refuse location area due to refuse vehicle backup. D.S. 2-02.2.1.A.12 Relocate pedestrian pathway. 6. Indicate curb openings for drainage. Indicate on-site and off-site flows (Q). 7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17 A Grading Plan/Review may be required due to the fill that may or may not be imported. 8. Closed unused driveways. Show adjacent driveways. D.S. 2-02.2.1.A.18 9. Indicate refuse container location, size and access thereto fully dimensioned. Demonstrate vehicle maneuverability fully dimensioned. Indicate a refuse enclosure detail as per D.S. 6-01.4.2 10. A back-up spur will be provided at the end of a row of parking if no ingress or egress is provided at the end. The spur will be a minimum of three (3) feet in depth, will have a three (3) foot radii, and will have a wheel barrier to prevent encroachment onto any unsurfaced areas. A minimum distance of three (3) feet will be provided between the back of spur and any wall, screen or other obstruction over six (6) inches in height. When the last space in a bay of parking is wider than eight and one-half (8 1/2) feet, the back-up spur can be refused in size, subject to approval by the Traffic Engineer. 11. As per the Federal ADA requirements, all wheel chair ramps shall have the Truncated Domes instead of the standard grooves shown on City of Tucson Standard Detail 207. Aside from the Truncated Domes, the wheel chair ramps shall be constructed in accordance with Standard Detail 207. Correct and revise. 12. Sheet 2 of 2, graphically indicate where the drainage detail is to be shown on the lot. 13. Indicate Water Harvesting Areas to be 6 inches. |
| 07/29/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. Indicate contour intervals along with the north arrow and scale. This should be placed together. D.S. 2-02.2.1.A.1 3. Submit a copy of the Lot combination recorded document. 4. Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Add note, "All roof spouts will be routed under any adjacent sidewalk." D.S. 2-08.3.1 & 4.1.E 5. Within all development, a continuous pedestrian circulation path is required. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets cannot be placed across the refuse location area due to refuse vehicle backup. D.S. 2-02.2.1.A.12 Relocate pedestrian pathway. 6. Indicate curb openings for drainage. Indicate on-site and off-site flows (Q). 7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17 A Grading Plan/Review may be required due to the fill that may or may not be imported. 8. Closed unused driveways. Show adjacent driveways. D.S. 2-02.2.1.A.18 9. Indicate refuse container location, size and access thereto fully dimensioned. Demonstrate vehicle maneuverability fully dimensioned. Indicate a refuse enclosure detail as per D.S. 6-01.4.2 10. A back-up spur will be provided at the end of a row of parking if no ingress or egress is provided at the end. The spur will be a minimum of three (3) feet in depth, will have a three (3) foot radii, and will have a wheel barrier to prevent encroachment onto any unsurfaced areas. A minimum distance of three (3) feet will be provided between the back of spur and any wall, screen or other obstruction over six (6) inches in height. When the last space in a bay of parking is wider than eight and one-half (8 1/2) feet, the back-up spur can be refused in size, subject to approval by the Traffic Engineer. 11. As per the Federal ADA requirements, all wheel chair ramps shall have the Truncated Domes instead of the standard grooves shown on City of Tucson Standard Detail 207. Aside from the Truncated Domes, the wheel chair ramps shall be constructed in accordance with Standard Detail 207. Correct and revise. 12. Sheet 2 of 2, graphically indicate where the drainage detail is to be shown on the lot. 13. Indicate Water Harvesting Areas to be 6 inches. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/23/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |