Permit Number: T05OT00598
Parcel: 11304297B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05OT00598
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: August 29, 2005
ACTIVITY NUMBER: T05OT00598
PROJECT NAME: The Narrows
PROJECT ADDRESS: 1040, 1042, 1044 East Halcyon Rd.
PROJECT REVIEWER: Patricia Gilbert

FLOODPLAIN USE PERMIT IS DENIED

SUBMITTAL REQUIRED: SITE PLAN, SITE PLAN/PERMIT APPLICATION

RESUBMITTAL REQUIRED: DRAINAGE REPORT, FLOODPLAIN USE PERMIT APPLICATION

Please note a new reviewer conducted this review.

1. Is the intent of this project to split the lot into three lots? Please address in the response letter.

2. The objective of a Hydrology Report is to establish finish floor elevations (FFE) for structures located in an area that is affected by 100-yr flows. Which this project is affected by 100-yr flows. The Hydrology Report does not establish FFEs for the structures. The floodplain use permit will not be approved until water surface elevations (WSE) and FFEs are established for each structure. A datum for the WSE and the FFE must also be provided. Clearly indicate the WSE, FFE and datum used.

3. Please note the above requested information must be on the site plan. The site plan will not be approved unless the FFE and WSE for each structure has been provided. The datum used must also be shown on the site plan.

4. Please note a condition of this permit contains a requirement that the applicant, or the applicant's authorized representative, complete a FEMA Elevation Certificate and is returned to DSD Engineering prior to approval of special inspection.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/31/2005 JMORALE1 OUT TO CUSTOMER Completed
08/31/2005 SUE REEVES REJECT SHELF Completed