Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T05OT00465
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. Label the existing right-of-way for Camilla and for Speedway. Label the street centerlines. DS 2-02.2.1.A.19 Refer to Sheet 2 of 2 of redlines for corrections. 3. Label the future MS&R right-of-way for Speedway (60 ft. ½ ROW). 4. The svts' for the corner of Speedway and Camilla are noted in redlines on Sheet 2 of 2. Keynote #5 should be 185' x 20' svt. Keynote #6 is not drawn correctly. Refer to redlines for svt location. Correct and revise. 5. The existing and future near svts' from PAAL onto Speedway are measured from the face (outside edge) of curb of the curb return. DS 2-02.2.1.A.10 Correct and revised. See Sheet 2 of 2 redlines. 6. Dimension the width of all ingress/egress driveways. DS 2-02.2.1.A.11 As per Keynote #3 a Right-of-way permit will be required. 7. Indicate all roof downspouts and sidewalk scuppers. Indicate a symbol or a keynote that identifies each item. DS 2-08.4.1.E Indicate a dimension detail of downspout and sidewalk scupper. 8. Dimension the existing and future sidewalk width. DS 2-02.2.1.A.21 9. Indicate if parking islands are to contain vegetation, water harvesting or filled with concrete. 10. New projects will provide centralized on-site refuse storage, collection and pickup areas. Indicate refuse container location and access thereto fully dimensioned. Demonstrate vehicle maneuverability fully dimensioned. Contact John Clark of Environmental Services @ 791-3175 ext. 1136 to reach an agreement that does not meet Development Standards 6-01 and to obtain a DSMR. 11. Please contact Dale Kelch @ 791-4259, for assistance for the Speedway driveway entrance location. Transportation Access Management Guidelines, 5.4 12. Indicate the proposed and or existing dimensions for all PAAL widths. DS 2-02.2.1.A.11 Dimension six-foot striped pedestrian walkway. |
| 04/01/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. A 10' interior landscape border is required along site boundaries of the adjacent residential property to the north per LUC Table 3.7.2-I 2. One canopy tree must be provided for every thirty-three (33) linear feet of the interior landscape borders per LUC 3.7.2.4 3. A 5' wall to screen residential zoned property from the vehicle use area is required per LUC 3.7.2-I. Show the location and height on landscape plan of existing CMU wall indicted on Sheet 2 of 2 of the Site/Grading Plan 4. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree per LUC 3.7.2.3.A.1.c. Include dimensions on landscape plan of all the canopy tree planters within vehicle use area. |
| 04/05/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Denied | 1. Relocate the accessible ramp outside the access aisle and provide a detail. Ramp shall conform to ICC/ANSI A117.1-2003 Section 405. 2. New sidewalks from both streets fronting the property must be accessible and at least four (4) feet wide. Please label and dimension the width and slope of sidewalks. (D.S. 2-02.2.1.A.20) |
| 04/05/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The following comments are based on a change of use from retail to personal service, resulting in a full code compliance review of the entire site. 1. Relocate the accessible ramp outside the access aisle and provide a detail. Ramp shall conform to ICC/ANSI A117.1-2003 Section 405. 2. Label and dimension existing and future sight visibility triangles. Per Engineering review redlines, SVT's need to be corrected. (D.S. 2-02.2.1.A.10) 3. A 24 foot wide PAAL is required at the crosswalk area near the loading zone. (D.S. 2-02.2.1.A.11) 4. Provide the loading space calculation (number and size required and provided). (D.S. 2-02.2.2.A.5) 5. The light pole is blocking the proposed pedestrian path coming from the new parking area. Relocate light pole. (D.S. 2-02.2.1.A.19) 6. New sidewalks from both streets fronting the property must be accessible and at least four (4) feet wide. Please label and dimension the width and slope of sidewalks. (D.S. 2-02.2.1.A.20) 7. If applicable, a barrier (i.e. curb, post bollards, fencing) is required to prevent vehicle from driving onto unimproved portions of the site. If this is required, please label and dimension unimproved areas and indicate the type of barrier proposed. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/06/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |