Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05OT00057
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 01/26/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Passed | |
| 01/26/2005 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Under general note eight (8) and the parking calculation please revise the proposed land use listed from "outdoor storage" to "Commercial Storage development designator 34, subject to: Sec. 3.5.10.1." (D.S. 2-02.2.1.A.31) 2. Label the zoning classification for the adjacent properties on the plan. (D.S. 2-02.2.1.A.28) 3. A back-up spur is required at the end of the driveway. Provide dimensions on plan. Refer to D.S. 3-05.2.2.D for design criteria. (D.S. 2-02.2.1.A.11) 4. The vehicle parking spaces provided are scaled at 29 feet in length yet the note states they are to be 20 feet in length. Please revise for consistency. (D.S. 2-02.2.1.A.8) 5. Per LUC sec. 3.3.4 "Commercial Storage" and LUC Sec. 3.3.3.5, two (2) Class 2 bicycle parking spaces are required. Provide a note under the parking calculation, which states the number and class type required and provided. In addition, indicate the location on the plan and provided a fully dimensioned detail. Refer to D.S. 2-09 for design criteria. (D.S. 2-02.2.1.A.9) (D.S. 2-02.2.2.A.4) 6. Label and dimension sight visibility triangles. (D.S. 2-02.2.1.A.10) 7. Dimension right-of-way for Freeway Industrial Loop. (D.S. 2-02.2.1.A.19) 8. All existing and proposed easements must be shown on the plan including width, type, and recording docket and page reference and whether they are private or public. (D.S. 2-02.2.1.A.20) 9. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
| 01/31/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit last approved landscape and NPP plans included Case # S99-053 to continue review. |
| 01/31/2005 | Andrew Connor | LANDSCAPE | REVIEW | Denied | 1. Submit last approved landscape and NPP plans included Case # S99-053 2. Provide a chain link fence and a 5' continuous wall along the entire Northeast site boundary per BOA Case # C10-00-19 dated 3/29/00 3. The Vehicular use area must include post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond unpaved areas on or off site and to prevent vehicles from driving onto unimproved portions of the site. Provide barricades for all the vehicle use areas including access to other portions of the site per DS 3-05.2.3.C.1 4. Areas where plants are susceptible to injury by vehicular or pedestrian traffic must be protected by appropriate means, such as curbs, bollards, or low walls Provide protection for Circidum floridum within parking lot per LUC 3.7.2.3.B |
| 01/31/2005 | Doug Williams | ENGINEERING | REVIEW | Denied | Lot 3 Freeway Industrial Park (DSD #T05OT00057) Engineering Division Review comments 2 February 2005 Doug Williams, Sr. Eng. Assoc. Please address the comments provided below. An over-the-counter review/approval may be arranged with me upon addressing/completing all comments provided for this submittal. Please contact me to schedule a time at 791-5550 Ext. 1189, or via email at Doug.williams@Tucsonaz.gov 1. Depict and label new concrete Driveway Aprons to be constructed (per Pima County/City of Tucson Standard Detail 206) at both driveway locations. 2. Dimension the ingress/egress and Parking Area Access Lane (PAAL) widths (DS 2-02.2.1 A 11). 3. Depict drainage patterns and proposed finish grades (DS 2-02.2.1 A 16). 4. Provide estimated cut/fill quantities. 5. Provide existing topographic contours at intervals not exceeding 2 feet, and/or spot elevations as pertinent with Benchmark based on City of Tucson Datum with City Field Book and Page # (DS 2-02.2.1 A 23). 6. Identify/label the wall as existing or proposed, and provide wall opening notes and/or detail(s) demonstrating site drainage/conveyance as approved in the Master Drainage Report for Freeway Industrial Park (DS 2-02.2.1 A 27). *** Please note that this subdivision's Detention/Retention basin appears to have been completed, however the final grading inspection approval has not occurred, and may be necessary prior to site plan approval *** If you have any questions, please contact me 791-5550 Ext. 1189, or via email at Doug.williams@Tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/08/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 02/08/2005 | SUE REEVES | REJECT SHELF | Completed |