Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05OT00004
Parcel: 124081520

Address:
1316 E 8TH ST

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T05OT00004
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2005 BLANCA ESPINO ENGINEERING REVIEW Approved 01-07-2005

FLOODPLAIN USE PERMIT NO. T05OT00004
ADDRESS: 1316 E. 8th St.
PROPERTY OWNER: Justin Cook
The applicant is authorized to use a portion of the City of Tucson the property described as (legal description): Drakes Lots 4, 5 & 6, BLK 21

1. This permit is for the purpose of a SFR within a FEMA floodplain.

2. The proposed building is impacted by the regulatory floodplain. The floodplain 100-year water surface elevation (WSE) just upstream of the (existing or proposed) building is 2414.00 feet. The building must be elevated above the floodplain 100-year WSE. This can be achieved by either building up the building pad to the 100-year WSE or higher, or elevating the building by any other acceptable method such as stem walls, piers, etc, depending on what the drainage report, the engineer or the owner is proposing. The building lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2413.00 (1 foot above 2412.00) feet above see level, NGVD 1929 as certified by a Registered Land Surveyor.

NOTICE
This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/04/2005 LISA LESNY OUT TO CUSTOMER Completed