Permit Number: T05CM06368
Parcel: 12908021G

Address:
1239 S CHERRY AV

Review Status: Completed

Review Details: SITE

Permit Number - T05CM06368
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: January 11, 2006
ACTIVITY NUMBER: T05CM06368
PROJECT NAME: The Bottle Shop
PROJECT ADDRESS: 1239 South Cherrybell Stravenue
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN


1. It is acknowledged that the entire parcel is not under review. However the proposed development must meet the criteria found under the Development Standard Site plan Content and Specifications 2-02. Be advised some of the comments below is required content and specifications found in DS 2-02. The submitted plan must meet DS 2-02, or submit the last approved site plan to meet the criteria of DS 2-02.

2. The northern and eastern lot lines are not shown. Clearly delineate all lot lines. Show bearings and dimensions. DS 2-02.2.1.A.5.

3. Provide (label and dimension) future sight visibility triangles for both ingress/egresses to Cherrybell Stravenue.. D.S. 2-02.2.1.A.10.

4. Show drainage patterns, proposed finish grades or add general note to sheet C1 that drainage patterns and finish grades can be found on the grading plan, sheet C2. DS 2-02.2.1.A.16.

5. Provide estimated cut and fill quantities on the site plan. DS 2-02.2.1.A.17.

6. Dimension the PAAL located east of the structure. DS 2-02.2.1.A.11.

7. Provide the recordation information (book and page) for Cherrybell Stravenue, 22nd street and Neff Street. Indicate if the roads are public or private. DS 2-02.2.1.A.18.

8. Cherrybell Stravenue is designated as a Collector Street per the MS & R Plan. Show on the plan Cherrybell Stravenue is a Collector Street per the MS & R Plan. DS 2-02.2.1.A.18.

9. As stated in the above comment Cherrybell Stravenue is designated as a Collector Street per the MS & R Plan with a full future ROW width of 64' and a ½ ROW width of 32'. Dimension from street centerline the ½ future ROW of 32'. Show future curb and sidewalk location. Face of future curb shall be located nine (9) feet from the future property line. Label appropriately. DS 2-02.2.1.A.19.

10. In addition to the above comment 22nd Street is also an Arterial Street per the MS & R Plan. Label 22nd Street as an Arterial Street. Show the ½ future ROW widths, curb and sidewalk location. DS 2-02.2.1.A.19.

11. This project is subject to intersection widening per the MS & R Map. Refer to the diagram located on the lower left hand corner of the MS & R Map found on the following web page, http://www.ci.tucson.az.us/planning/maps/city/msr.pdf. Label the site plan accordingly and show dimensions.

12. For a driveway/PAAL to a collector street 25' curb returns are required. Revise the plan to indicate 25' curb returns for both driveways to Cherrybell Stravenue.

13. All easements of record must be graphically shown on the plan together with recording docket and page reference. There is an overhead utility line located in the northwest corner of the site. Is there an easement in this location? Clarify in the response letter and revise accordingly. DS 2-02.2.1.A.20.

14. It is not clear if Cherrybell Stravenue has existing curbs and sidewalks. Again from reviewing an aerial photo it appears there are curbs along Cherrybell Stravenue. Dimension form street centerline to the existing curb location. Label accordingly. DS 2-02.2.1.A.21.

15. Is their sidewalk along Cherrybell Stravenue (within the ROW)? Sidewalks are required as part of new development of all properties. All new development shall provide 6 foot wide sidewalk along the entire length of the proposed development. If existing sidewalk is already located with the ROW indicate accordingly. Otherwise indicate a proposed 6' sidewalk within the ROW. Be advised it is recommended to locate the new sidewalk in the future sidewalk location to avoid having to relocate the sidewalk upon future ROW widening. Revise accordingly to show sidewalk along entire length of the proposed development. DS 3-01.2.7.B., DS 3-01.3.3.A.

16. Dimension from the street centerline of 22nd street and Neff Street to the existing curb and sidewalk locations. Label appropriately. DS 2-02.2.1.A.21.

17. Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number or add a general note to the site plan sheet C1 that contours and spot elevation can be found on the grading plan sheet C2. DS 2-02.2.1.A.23.

18. After reviewing the aerial photo it is not clear if southeast and east of the large structure to be demolished is paved or not. Clarify on the plan view and in the response letter. If this area is dirt, the access to Neff Street must be blocked with an appropriate barrier. Revise accordingly.

19. Additional comments could be forthcoming based on the number of comments.
01/12/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Additional tree is required for vehicle use area to the east.
01/12/2006 ANDREW CONNOR NPPO REVIEW Approved 1. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Additional tree is required for vehicle use area to the east.
02/22/2006 JMORALE1 ZONING HC SITE REVIEW Needs Review
12/23/2005 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/22/2006 JMORALE1 OUT TO CUSTOMER Completed