Permit Number: T05CM06363
Parcel: 137270990

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T05CM06363
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2007 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens FOR: David Rivera
Lead Planner Principal Planner

PROJECT:T05CM06363
1430 W. Valencia Rd.
Midvale Medical - Dental Plaza
Site Plan

Transmittal date:5th Review 6/22/07

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. DS 2-02.2.1.5 The copy of the lot combination covenant provided is not complete. Provide on the document the Case # T05CM06363 and then re-record the document. Provide on the site plan the new recordation information for the re-recorded covenant (docket and page).

2. DS 2-02.2.1.11 Provide a copy of the cross access agreement with the property to the west. Provide on the site plan the docket and page recordation information for the cross access agreement.

3. DS 2-02.2.1.12 Clearly indicate the location of all truncated domes for all handicap ramps which access vehicular use areas. The truncated domes indicated on detail 7 of SP-2 are not in the correct locations. A 24" deep strip across the entire width of the landing abutting the pavement is required. Se ANSI 117.1-2003 Sec. 406.12 and 406.13.

4.These changes are minor in nature and can be approved over the counter by setting an appointment with me.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961
06/21/2007 SUNRISE ENGINEERING ENGINEERING REVIEW Approved
06/21/2007 TERRY STEVENS ZONING HC SITE REVIEW Denied see zoning comments

Final Status

Task End Date Reviewer's Name Type of Review Description
06/26/2007 SUE REEVES OUT TO CUSTOMER Completed
06/26/2007 SUE REEVES REJECT SHELF Completed