Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T05CM06350
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T05CM06350 .. 2560 S KOLB ROAD .. WALGREEN'S CANOPY .. DGL .. 1ST REVIEW .. 1/11/06 .. S1. Provide Site Plan by Architect of Record showing Property lines for the site and the location of the work dimensionally located from two adjacent property lines and adjacent structures. S2. Provide Completed code review checklist by Architect of Record. S3. Provide drawings and documents with a minimum font size of 1/8" for review and record purposes, ref S1.0 and S2.0. S4. Utilize current Code designations on drawings, ref T1.0. S5. The Type of Construction is limited to a single Type of Construction for a Building, if more than one Type of Construction exists show required Fire Walls and Hourly fire-rating of these Walls on the drawings. S6. Separate permits required for signs. S7. Provide specifications for architectural materials of construction ref A1.0, including : 1. Built-up membrane roofing. 2. E.I.F.S. 3. Fasteners. 4. Flashing. S8. Provide architectural details, including : 1. Splicing of built-up membrane roof (new to existing). 2. Canopy facia to existing wall. S9. Provide addressing per Pima County Addressing Ordinance. S10. Structural review and comments will take place when readable drawings are submitted, see comment S3 above. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
| 12/21/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 12/21/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 12/21/2005 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 12/21/2005 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 12/21/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 12/21/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 12/21/2005 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/29/2005 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | 1.Provide circuit and panel designation. 2.Provide panel load calculations with circuit loads 3.Indicate overcurrent protection 4.Indicate fixture,lamps wattages etc. 5.Provide the existing service loads and the size of the existing service lateral conductors. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/03/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 02/03/2006 | SUE REEVES | REJECT SHELF | Completed |