Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T05CM06241
Parcel: 13401002B

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T05CM06241
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2006 PAUL MACHADO ENGINEERING REVIEW Approved March 27, 2006 (No Special Inspection Required).

FLOODPLAIN USE PERMIT NO. T05OT03195
ADDRESS: 250 S. Harrison Road
PROPERTY OWNER'S NAME: City of Tucson

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as:

Halcyon Acres irregular parcel (134-010-02B) in Lot 2 adjacent to Harrison Road for the purpose of a tenant improvement in a commercial building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35)

1. All work shall conform to the attached plans (Drainage Report and all improvement plans) which are made part of this permit.

2. The existing drainage patterns at the property lines shall not be obstructed.

3. The combined tenants improvements on the commercial building shall not exceed 50% of the cost of the commercial building alone (excluding land cost).

4. The proposed cost of the tenant improvement is $125,000. The estimated cost of the building alone is $264,000. The percentage of improvements included in this FUP is 47%.

5. Any proposed improvements on any existing structures shall not encroach into the Erosion Hazard Setback (15') as set by the drainage report included with this Flood Plain Use permit.

6. Any additional work proposed on this building within 6 months of this date that would be exceed the original 47% improvement proposed with this Flood Plain Use permit would considered to be full code compliance.

7. This permit applies to the current proposed tenant improvements only. Any additional improvements on site, such as and to detached structures, site improvements, additional parking etc., will require a new drainage submittal and Flood Plain Use permit.

8. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T05OT03195. For information please call 791-5550."

9. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

10. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

11. Adhere to specifications outlined in Section C, C2 of the elevation certificate.

12. Return of the completed elevation certificate must be submitted to the Records Department, 201 N. Stone Ave. prior the issuance of a Certificate of Occupancy.

13. Any walls to be constructed will require a separate Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section.

(EXPIRATION DATE) Month: 03 Day: 27 Year: 2006

Note: The final inspection or certificate of occupancy will be on hold until the Elevation
Certificate is completed and returned to our office.


APPLICANT NAME: D. Christopher Barta
ADDRESS: 700 N. Stone Ave.
PHONE NO.: (520) 882-9944


________________________ _____
APPLICANT'S SIGNATURE DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
04/06/2006 CRAIG GROSS ZONING HC SITE REVIEW Approved
04/06/2006 CRAIG GROSS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/17/2006 SUE REEVES APPROVAL SHELF Completed
04/17/2006 ADRIANNE OLIVO OUT TO CUSTOMER Completed