Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T05CM06122
Parcel: 127030200

Address:
5550 E 1ST ST

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T05CM06122
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2006 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.
INCLUDE EMAIL ADDRESS OF ENGINEER/ARCHITECT/DESIGNER WITH NEXT SUBMITTAL
PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Provide power requirements for both new and existing EC, such that it may be verified that there are no load changes, or any changes to existing overcurrent protective devices. The above shall be clear on the plans.
2. Provide power requirements, on plans, for new hood, including such items as exhaust fan, lighting, controls. Provide electrical power.
12/12/2005 GERRY KOZIOL WWM REVIEW Passed
12/12/2005 JIM EGAN FIRE REVIEW Denied 1. Show entire building on plan. Indicate existing exits. Required exit doors shall swing in direction of egress. Indicate panic hardware.
2. Indicate fire rating/opening protection required for east and west exterior walls.
3. Indicate fire rating for exit corridor. All openings protected with minimum 20-minute fire rated opening protectives.
4. Indicate Type 1 hood provided for cooking appliances. Fire suppression system required.
5. Provide correct code review checklist.( No B-2 occupancy or Type 5 1-hr construction in 2003 IBC.
12/16/2005 ROBERT SHERRY WATER REVIEW Approved
12/16/2005 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The applicable code for all commercial plumbing projects is the 2003 Uniform Plumbing Code with Local Amendments.
2. Provide a natural gas piping design, including the piping layout on a floor plan and a natural gas schematic showing the sizes, loads and developed lengths for all of the natural gas piping. Reference Section 103.2.3, UPC 2003.
12/16/2005 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. The 2003 International Mechanical Code with Local Amendments is the relevant code for this project.
2. Revise the font size used on the drawings to a minimum of 1/8 inch. Reference Section 302.3, Uniform Administrative Code, 1997.
3. Provide listing information (i.e. manufacturer's cut sheets) for the new rooftop air conditioners, the makeup air unit, and the exhaust fan for the new hood. Reference Section 106.3.1, IMC 2003.
4. Provide the installed weight of the rooftop equipment. Reference Section 106.3.1, IMC 2003.
5. Show the size, routing, and termination of the condensate drains for the rooftop units and for the split-system evaporator. Reference Section 307.2, IMC 2003 and Section 807.2, UPC 2003.
6. Provide a complete design for the installation of the Type I hood, grease duct, and the exhaust fan. Reference Sections 106.3.1,506, and 507, IMC 2003.
7. Provide structural calculations to show that the roof structure will accommodate the weight of the hood, grease duct, exhaust fan, and the possible weight of a person working on the hood. Show how the hood will be supported from the structure while maintaining the required clearances from combustible construction and complying with the listing requirements of the hood. Note: the IMC considers wood covered by gypsum board to be combustible construction. Reference Section 507.6, IMC 2003.
8. Revise the site plan to clearly show that the termination of the exhaust fan for the Type I hood complies with Section 506.3.12.3, IMC 2003. Note: color graphics are not suitable for microfilm records. Please use black ink for all parts of the drawing. Reference Section 302.3, Uniform Administrative Code, 1997.
9. Provide information to show that the make up air for the kitchen hood complies with Section 508.1.1, IMC 2003.
12/19/2005 CHRISTY FOREMAN BUILDING-COMMERCIAL REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES
STRUCTURAL REVIEW COMMENTS

DATE: 12/20/05
ACTIVITY NUMBER: T05CM06122
PROJECT NAME: 5550 E. 1st. St.
PROJECT ADDRESS: Church
ARCHITECT / ENGINEER: Alan Roberts
PROJECT REVIEWER: Christy Foreman


TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS.

1) Code analysis Occupancy Group appears to be incorrect. Church is a assembly occupancy see IBC 2003 section305. Clarify separated or non-separated use.
2) Justify 20% cost of construction being spent toward accessibility requirements per code section 3409.6 IBC 2003. Provide itemized breakdown of costs for items on the drawings.
3) It appears a lot combination has not been completed for this building.
4) Clarify existing framing to justify tributary width for glulam beam.
5) Justify column with structural calculations.
6) Justify footing with structural calculations.
7) Provide weight of exhaust hood and justify with structural calculations the existing framing can carry the new load.
8) Provide detail for attaching exhaust hood to existing structure.
9) It appears last addition to church in 1993 was never approved by C.O.T. Structural reviewers. Please justify / clarify distance of this addition from existing residence.
10) Provide justification that existing roof framing can carry new loads of the mechanical equipment shown on sht. M1.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/12/2006 JMORALE1 OUT TO CUSTOMER Completed
01/12/2006 SUE REEVES REJECT SHELF Completed