Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T05CM06065
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/20/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 01/20/2006 | JIM EGAN | FIRE | REVIEW | Denied | 1. Provide verifcation that construction of smoke barrier is in conformance with 2003 Sec. 709. 2. Doors in smoke barriers shall conform to Section 709.5. 3. Exit signs at smoke barriers shown incorrectly. (Sht. a2.0) |
| 01/23/2006 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 02/03/2006 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | SUBJECT: St Mary's Hospital South Wing 3rd Floor Rehab area TI Engineering Review ADDRESS: 1601 West Saint Mary's Road, Tucson Arizona 85745 PROPERTY OWNER: Carondelet St. Mary's Hospital and Health Center, Carondelet St. Mary's Hospital and Health Center, Attn: Chuck Spencer 349-0131 LOCATION: T14S R13E Section 10 A portion of Parcel 116-15-088L, PTN FRAC LOTS 1 2 10 11 & 12 N2 SE4 LYG W OF SILVERBELL & S OF ST MARY'S & N OF ANKLAM REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T05CM06065 SUMMARY: The TI plans and building review documents, described as 3rd Floor Inpatient Rehabilitation area of the South Wing hospital building, were received and reviewed by Engineering Division. The Floodplain Use Permit has been issued with the demolition plans with the floodplain use permit application T06OT00164, that included valuation of the improvement and location map, for the purpose of tenant improvements to an existing, non-conforming floodprone structure. Engineering recommends approval of the TI plans. CONDITIONS OF PERMIT: 1) The associated improvements are with permit activity number T05CM06065 (Demo / TI plans), T06OT00164 (Floodplain Use Permit). 2) Any improvements to the structural building for this project are considered a substantial improvement to an existing floodprone structure if the value of this new improvement is 50% or more than the value of the existing structure in present day value. If the project is determined to be a substantial improvement, and, if it is determined that the lowest floor elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for floodproofing will be required and shall conform to City of Tucson and FEMA floodplain development requirements. 3) Cumulative values shall be accounted for each building structure, so that tracking of the 50% status is current. 4) All future St Mary's building structures 2006 shall be submitted with a Floodplain Use Permit application. It shall be the responsibility of Carondelet Health Network, or its authorized agent, to supply the following with future Floodplain Use Permit Applications: a) Value of improvement in U. S. Dollars. b) Type of assessment used for valuation. c) Cumulative value of the building structure. d) A calculated percent improvement. e) Title of the improvement. f) Description of improvement. g) Provide 8-1/2" x 11" map locating improvement. h) Provide permit activity number(s). 5) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents. 6) This permit is specific to the improvements for the rooms for the building specified as the construction of the interior improvements for the 3rd floor area of the south wing as shown on this plan. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. 7) Copies of the improvement plans/permit documents shall be kept in a readily accessible location on site at all times. If you have any questions, I can be reached at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/07/2006 | AOLIVO1 | OUT TO CUSTOMER | Completed |
| 02/07/2006 | SUE REEVES | REJECT SHELF | Completed |