Permit Review Detail
Review Status: Completed
Review Details: CELL TOWER/ANTENNAS
Permit Number - T05CM05935
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/17/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T05CM05935 .. 2645 N CRAYCROFT ROAD .. CELLSITE ON TMC PARKING GARAGE .. DGL .. 1ST REVIEW .. 1/19/06 .. S1. Provide completed code review checklist, see DSD website Forms at www.tucsonaz.gov. S2. Provide details and material specifications for : 1. Antennas. 2. Antenna mounting system. 3. Anchorage of fencing and equipment to garage decking, walls and columns. 4. Sealing of holes cut through garage walls and decking, addressing weatherproofing and fire-rating as necessary. S3. Clarify callouts on drawings A-2 and A-3, referring to details on a drawing designated A-4, should these be S-1? S 4. Special inspection required for : 1. Epoxy anchors. 2. Field welding. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
| 01/20/2006 | DAN CASTRO | PLANNING-CITY HALL | REVIEW | Approved | |
| 01/25/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 01/28/2006 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 01/31/2006 | JAY HOGAN | COMMUNICATIONS | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/17/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 02/17/2006 | SUE REEVES | REJECT SHELF | Completed |