Permit Review Detail
Review Status: Active
Review Details: 3RD PARTY REVIEW-COMMERCIAL
Permit Number - T05CM05850
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/25/2006 | DROBEY1 | WWM | REVIEW | Needs Review | |
| 05/25/2006 | DROBEY1 | ENGINEERING | REVIEW | Denied | DATE: June 26, 2006 SUBJECT: Pre-fabricated Metal Building- Site Plan Review TO: Glenn Cook LOCATION: 1538 W Prince Rd, T13S R13E Sec27, Ward 3 REVIEWERS: Jason Green, CFM ACTIVITY: T05CM05850 SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted site plan, Sheet A1. The site plan is not approved at this time. Please address the following comments: SITE PLAN COMMENTS: 1) DS Sec.2-02.2.1.A.4: Revise the location map to accurately show the parcel location. Identify conditions within the square mile area shown on the project location map located on Sheet A1, such as subdivisions, major streets, and major watercourses. Reference recorded subdivision plats by book and page numbers. 2) DS Sec.2-02.2.1.A.10: Show existing and future sight visibility triangles on plan view. Refer to DS Sec3-01.5.1 for sight visibility triangle procedures and criteria. Parking spaces, signs, landscape and walls will not be approved within the future right-of-way. Provide a note on the site plan to state no structures and vegetation is allowed within 30" to 72" in height and will not be placed within the sight visibility triangles. 3) DS Sec.2-02.2.1.A.12: Revise the site plan to show the required continuous pedestrian circulation path that must connect all public access areas of the proposed building and the circulation path located on Prince Road. 4) DS Sec.2-02.2.1.A.16: Provide a detail for the location and type of drainage structure, label and dimension proposed scuppers, that are used for collecting onsite roof drainage at all pedestrian sidewalk. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk. 5) DS Sec.2-02.2.1.A.17: Provide estimated cut and fill quantities on the site plan for grading plan purposes. 6) DS.2-01.2.1.A.19: Provide dimensioned Major Streets and Routes Plan right-of-way for Prince Road. 7) DS Sec.3-01.3.3.A: Revise the site plan to show the required future 6-foot wide sidewalk with curb along the street frontage of Prince Road. Per the adopted Mayor and Counsel policy all sidewalks along MS&R right-of-ways for arterial and collector streets require 6-foot wide sidewalks. 8) DS Sec.2-02.2.1.A.20: Provide recording information for the existing right-of-way for Prince Road. 9) DS Sec.2-01.2.1.A.23: Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and Page number. 10) DS Sec.2-02.2.1.A.32: Provide dimensions for refuse container, show or label gates or doors for trash enclosures. The enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between steel pipes that are required between the container and the enclosure's rear and sidewall. Refer to DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction. Show maneuverability for refuse vehicles in plan view. 11) DS Sec.3-01.2.7 A: Revise the site plan to reflect handicap access ramps with truncated domes. Please refer to this standard and the figures provided for additional street design requirements, including curb access ramps, utilities, landscaping, etc. 12) DS Sec.3-01.3.2.C: Depict and label 25' radii concrete curbs/headers per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the Prince Road driveway egress and ingress. The curbs/headers should be constructed at the edge of pavement, which must also be depicted on the site plan. 13) Provide water-harvesting areas, depressed 6-inches, shown in plan view to provide for onsite drainage. Refer to the City of Tucson Water Harvesting Guidance Manual, Ordinance # 10210, for recommendation on how to construct and maintain the required water harvesting areas. GENERAL COMMENTS: Please provide a revised site plan and a drainage statement that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the site plan. Please enclose "redlines" with the resubmittal package for reference. For any questions or to schedule a meeting, call me at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 05/25/2006 | BROWN & ASSOCIATES | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | RECEIVED | |
| 05/25/2006 | DROBEY1 | ZONING | REVIEW | Needs Review | |
| 05/25/2006 | DROBEY1 | WATER | REVIEW | Needs Review | |
| 05/25/2006 | DROBEY1 | FIRE | REVIEW | Needs Review | |
| 05/25/2006 | ANY | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Active |