Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM05678
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 06/26/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | According to the landscape plan and photographs submitted with the application for exception, protected native plants are located on site (Prosopis velutina, Native Mesquite) and subject trees are going to be removed from site. NPPO plan is required per DS 2-15.0. Include an aerial photograph, taken within a maximum of three (3) years of submittal, at a minimum scale of 1" = 60' showing the site's boundaries, the locations of all Protected Native Plants within those boundaries, and the plants' identification numbers keyed to the inventory list in Sec. 2-15.3.1.A.2. |
| 06/26/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | According to the landscape plan and photographs submitted with the application for exception, protected native plants are located on site (Prosopis velutina, Native Mesquite) and subject trees are going to be removed from site. NPPO plan is required per DS 2-15.0. Include an aerial photograph, taken within a maximum of three (3) years of submittal, at a minimum scale of 1" = 60' showing the site's boundaries, the locations of all Protected Native Plants within those boundaries, and the plants' identification numbers keyed to the inventory list in Sec. 2-15.3.1.A.2. |
| 07/19/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | To: Client Robert Lanning DATE: July 19, 2006 FROM: Jose E. Ortiz, PE Engineering Division SUBJECT: 2921 N. Geronimo Ave Site plan T05CM05678 (Second Review) T13S, R13E, Section 36 RESUBMITTAL REQUIRED: Site Plan The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please remove the revision clouds. I know that this may cause some confusion based on the information you may have received in the past from DSD, but the intent of the revision clouds is for revisions made to the plan set after DSD has stamped and approved the plans. Prior to approval no revision clouds are necessary. 2. The existing contour information has been removed please place this information back on the site plan. Due to the minimal comments generated by the Engineering review DSD Engineering will accept an over the counter review at the next submittal for final approval to the site plan. Please coordinate with the over reviewer to determine their willingness to conduct an over the counter review. If you have any questions, I can be reached at 791-4259 ext. 305 Jose.Ortiz@tucsonaz.gov Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 office (520) 879-8010 fax C:/ 0000 O. Street Address |
| 08/16/2006 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens FOR: David Rivera Senior Planner Principal Planner PROJECT:T05CM05678 2921 N. Geronimo Apartments Site Plan Transmittal date: 2nd Review 8/17/06 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Per DS 2-02.2.1.6 Provide the number of existing bedrooms for existing structures. 2. Per DS 2-20.2.1.9 The bicycle parking spaces location note appears to have been inadvertently dropped from the plan. Please indicate the location of the Class 2 parking rack. 3. In detail 1/A-1 indicate the height from grade to the bottom of the handicap parking sign as 7'-0". 4. The above comments are minor in nature and can be approved over the counter by setting an appointment with me. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. |
| 08/17/2006 | TERRY STEVENS | ZONING HC SITE | REVIEW | Denied | see zoning comments |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/25/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/25/2006 | SUE REEVES | REJECT SHELF | Completed |