| 11/14/2005 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 11/14/05 ACTIVITY NUMBER: T05CM05674 PROJECT NAME: DECK FOR CONTROLLED GIRAFFE FEEDING PROJECT ADDRESS: 1100 S. RANDOLPH WY ARCHITECT / ENGINEER: SWAIM ASSOCIATES PROJECT REVIEWER: Christy Foreman TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1) Size of thru-bolts @ 4/A1.0 to secure guardrail. 2) Specify connectors / thru-bolts detail 203A/S1.0 and 203/S1.0. 3) It appears longest span for exterior support beam equals 9'-11" dtl. 1/9.1.0. Structural Calculations sht. 2 justifies only 8'-0" span. |