Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM05563
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/06/2005 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | December 5, 2005 City of Tucson Development Services Department 201 North Stone Avenue Tucson, AZ 85701 RE: 5081 SOUTH FREEMONT AVENUE – 1ST REVIEW CITY OF TUCSON LOG NO T05CM05563 WILLDAN PROJECT NO. 13881-5029 The initial review for the above project has been completed. The following items reflect original comments, which remain unaddressed and require a written response indicating any action to be taken. In order to facilitate a shorter back-check time, all corrections and revisions shall be made on the original plans and two new COMPLETE sets of prints shall be returned along with all redline prints. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets as well as highlighting all changes with appropriate revision number, revision date, and “cloud bubbles”. Pen or pencil corrections on final prints will not be acceptable. Please return comment drawings with your re-submittal. Should you have questions regarding the comments herein, please contact your plans examiner John Stigalt. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms R-3 Carport Patio N/A IIIB 1360 336 140 No Yes GENERAL COMMENTS: This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2000 IMC, 2000 IECC, 2002 NEC codes with local modifications, and the 1994 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. ARCHITECTURAL COMMENTS: Sheet 4 Show on the plans that the weep screed will be a minimum of 4” above the earth and a minimum of 2” above paved surfaces. Reference section R703.6.2.1 IRC. Sheet 5 Show justification on the plans by using the 1/300 calculation instead of the 1/150. To use the 1/300 calculation there must be more than 50% but not more than 80% of the ventilation is to be at the upper half of the space to be vented at least 3’ above the eave or cornice or a vapor barrier with a minimum of 1 perm is to be installed. Reference section R806.2 IRC. STRUCTURAL COMMENTS: Sheet 3 In the truss calculations, please include in the calculations the weight of the roof top HVAC unit. Reference sections R301.1 and R802.10.1 IRC. PLUMBING COMMENTS: Sheet 7 Annotate on the plans that a thermal expansion tank will be installed to relieve the momentary pressure on the building supply. Reference section 608.3 UPC. Please revise the fixture unit schedule to reflect the fixture unit numbers assigned in Table 6-3 and 7-3 of the 94 UPC. Please include all appliances in the fixture unit schedule. The hose bibs were not included in the fixture unit schedule. Reference section 103.2.3 of the 1994 UPC. MECHANICAL COMMENTS: Sheet 8 Please coordinate the mechanical floor plans with the electrical floor plans for the placement of the exhaust fans. Reference section R106.1.1 IRC. Please remove all reference(s) to the “Uniform” codes and replace with the current adopted code that is the 2003 IRC. Reference the City of Tucson adopted codes. ELECTRICAL COMMENTS: Sheet 6 Please provide cut sheets and calculations for all the exterior light fixtures. The calculations shall be based on the maximum wattage that the fixture is listed for which will provide the maximum lumens per fixture. Reference the City of Tucson Outdoor Lighting Code. Annotate on the plans that the current adopted code is the 2003 IRC. Reference the City of Tucson adopted codes. Please revise keynote #11 to read that all branch circuits supplying outlets to bedrooms shall have arc fault protection. The note reads that all 15 and 20 receptacle outlets shall be protected. Reference section E3802.11 IRC. Annotate on the plans that the outlets not on a dedicated circuit in the laundry area will be GFCI protected. Reference section E3802.2 IRC. Please show how the wiring in the laundry room will be protected. Reference section E3702.3.2 IRC. ENERGY CODE COMMENTS: Sheet 3 The plans indicate that R-19 with 2” x 6” walls are to be used yet the energy calculations indicate that R-13 with 2” x 4” walls are to be used. Please clarify. Reference section R106.1.1 IRC Sheet 7 Annotate on the plans that heat traps will be installed on the inlet and outlet piping on the water heater. Reference section 504.7 IECC. ACCESSIBILITY COMMENTS: Not part of this review Sincerely WILLDAN Martin Haeberle, C.B.O. Building Official |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/07/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 12/07/2005 | SUE REEVES | REJECT SHELF | Completed |