Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM05544
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/16/2006 | STANTEC | 2ND PARTY REVIEW | REVIEW | Denied | March 15, 2006 To: City of Tucson Development Services Department 201 N. Stone Avenue, First Floor Tucson, Arizona 85701 Attn: David Mann, P.E., Building Code Division Cc: Rudi Graessle - Drafting 7020 E. Calle Orion Tucson, Arizona 85710 Re: Ried Residence - Additions to existing residence City of Tucson No. T05CM05544 Stantec Project No. 816-30015-01 (077) Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back-check time, we request that you please provide revised plans and calculations, clouding any changes, along with a written response to each of the noted items indicating the action taken. SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2003 International Residential Code (IRC). Applicants may reference the 2003 UPC for plumbing. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL: Denote what code cycle the drawings are based upon. Upon the drawings. Reference to ‘UBC’ tables are now non-compliant. The ‘IBC’ is the enforced and recognized standard. ARCHITECTURAL: There are no comments to address. STRUCTURAL: Provide detailing of how the existing stairway/dining room widow unit was enlarged. What is 4-WUDH3022? The reviewer can only rely upon the drawings. The stairway window expands from an eight-foot segmented to a new ten-foot segmented glazing within the documents submitted. Provide detailing of how the existing widow unit was enlarged at the new kitchen location. The reviewer can only rely upon the drawings. The kitchen window unit’s jamb decreases from a 16-inch segment to an 8-inch segment. PLUMBING PLANS: There are no comments to address. MECHANICAL PLANS: There are no comments to address. ELECTRICAL PLANS: There are no comments to address. MODEL ENERGY CODE: There are no comments to address. -End of Review- If you have any questions, please call (520) 750-7474. Sincerely, Stantec Consulting Inc. Steven L. Nygren, R.A. Senior Plans Examiner SLN:sln |
03/20/2006 | AKLAPPE1 | WWM | REVIEW | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/20/2006 | AKLAPPE1 | OUT TO CUSTOMER | Completed |