Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM05525
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2005 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | December 5, 2005 City of Tucson Development Services 201 North Stone Avenue Tucson, AZ 85701 RE: MANLEY RESIDENCE ADDITION – 1ST REVIEW CITY OF TUCSON LOG NO.: T05CM05525 WILLDAN PROJECT NO. 13881-5027 The initial review for the above project has been completed. The following items reflect original comments, which remain unaddressed and require a written response indicating any action to be taken. In order to facilitate a shorter back-check time, all corrections and revisions shall be made on the original plans and two new COMPLETE sets of prints shall be returned along with all redline prints. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets as well as highlighting all changes with appropriate revision number, revision date, and “cloud bubbles”. Pen or pencil corrections on final prints will not be acceptable. Please return comment drawings with your re-submittal. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms U Na VB 2213 No No GENERAL COMMENTS: This project has been reviewed for conformance with the 2003 IRC, 1997 UAC. Any revisions to this plan will require an additional review and approval by Willdan. ARCHITECTURAL COMMENTS: Reviewed and accepted STRUCTURAL COMMENTS: Sheet A1.2 Revise footing details to reflect the required 12” into undisturbed soil for the minimum depth of the footings. Reference section R403.1 IRC. Sheet A1.3 Plans do not reflect the required header for the opening to the garage. Revise plan. The exterior walls over 50 feet exceed the maximum allowable length without an interior braced wall line. Provide an interior braced wall line with a maximum spacing of 50 feet or a lateral analysis by a licensed engineer. Reference section R602.10.1.1 IRC. PLUMBING COMMENTS: N/A MECHANICAL COMMENTS: N/A ELECTRICAL COMMENTS: Sheet A1.1 Provide wire size, conduit size and grounding methods for feeder to garage. Reference section E3507.3 IRC. Include cut sheets and calculations for all exterior lighting on site showing compliance with the City of Tucson outdoor lighting code. A copy of the ordinance is attached. ENERGY CODE COMMENTS: N/A ACCESSIBILITY COMMENTS: N/A Sincerely WILLDAN Martin Haeberle, C.B.O. Building Official MAH/sb |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/07/2005 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 12/07/2005 | SUE REEVES | REJECT SHELF | Completed |