Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM05428
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/02/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T05cm05428 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. Floor Plan 1. Carport as defined by 2003 IRC, is open on two sides. Thus this so-called carport is actually a Garage and must comply with R309.2. Structural Plan 1. Epoxy and field welding requires special inspection. Submit form. 2. 8/A4 - 8/4" diameter anchor bolt? Is a 2" anchor bolt the intent? Also specify footing size under this area (detail 5 & 4). 3. 4/A4 and 5/A4 - Specify rebar in 12" CMU 4. Justify Truss construction. 5. Justify steel frame in kitchen doorway. 6. 9/A4 - 6x12 beam is noted. Roof plan notes 6x6. Clarify. Specify connection of beam to top plate. Electrical Plan 1. Provide smoke detector in vicinity of sleeping area (i.e. garden room) per R313. 2. Size underground feeder to panel B. 3. Where ceiling fans are shown on the plans, provide a note indicating only approved outlet boxes shall be used, per E4001.6. 4. Show locations of smoke detectors per R313. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms shall be equipped with battery operated smoke detectors per R313.1.1. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. 5. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/04/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |