Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM05363
Parcel: 11106100B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05CM05363
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/30/2006 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Approved
03/31/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: March 31, 2006
ACTIVITY NUMBER: T05CM05080
PROJECT NAME: Schulte Duplex
PROJECT ADDRESS: 3530 E. Monte Vista
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. It is acknowledged that John Clark of Environmental Services has accepted the current proposal. However in the letter from John Clark dated October 7th, 2005, he clearly states, "Side wall protection is required with a clear area of 10' by 10'." Detail B1 on sheet C1.1 does not show side wall protection. Per DS 6-01.4.2.C.2. steel pipes are required at the side walls of a solid waste enclosure. Please indicate steel pipes at the side walls of the solid waste enclosure, be aware the concrete slab (10' by 10' clear area) will need to increase in size to accommodate the steel pipes.
05/13/2006 DAVID RIVERA ZONING REVIEW Denied 05/13/06

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. Zoning has reviewed the building plans but cannot approve them at this time until the plans have been completely approved through the commercial review process.

2. A site card with DSD approvals by Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO including the approved development plan stamped for site plan approval and signatures is required before the grading plan can be approved by Zoning. Two copies of the CDRC approved tentative plat/development plan, landscape and NPPO plans are to be submitted with the grading plan packet for processing and approval as a site plan. No fees are involved in re-stamping the development/tentative plat plans as an approved site plan. The tentative plat/development plan may be walked through for stamps and site card sign off. Submit the following: two copies of the stamped development plan, landscape and NPPO plans must be included with the grading plans packet processed together for site approval.

3. Zoning will re-review and approve the building plans on the next submittal providing the stamped and approved site plans are included with the building plan package and the building structural portions of the plan review have been approved. See comment 2 for additional info regarding the site plan process.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/18/2006 ADRIANNE OLIVO OUT TO CUSTOMER Completed
05/18/2006 SUE REEVES REJECT SHELF Completed