Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM05332
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/21/2005 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Approved | 1) CLARIFY LOCATION, DISTANCE TRAVELED, AND ACCESSIBILTY OF RESTROOM FACILITIES. RESTROOMS APPEAR TO NOT BE ACCESSIBLE. CHAPT 3409.6 CLARIFY 20 % COST OF CONSTRUCTION IS BEING SPENT TOWARDS METTING ANSI A117.1 2003. CLARIFY MODIFACATIONS BEING MADETO ITEMS THAT ARE NOT NEW TO T.I. SPACE. 2) PROVIDE FULL WALL SECTION FOR EACH CONDITION AND CLARIFY LATERAL BRACING IF REQUIRED. PROVIDE FLOOR BRACING FOR WALLS THAT ARE NOT FULL HEIGHT. PROVIDE STRUCTURAL CALCS. TO JUSTIFY YOUR DETAIL. SEE SECTION 1621.1.2. SEE DETAIL 5/A3 - HTT22 SIMPSON ANCHOR NEEDS TO BE INSTALLED AS SPECIED BY MANUFACTURER. WOOD 2X4 STUD NEED TO HAVE ATTACHMENT TO STRUCTURAL FRAMING. STRUCTURAL CALCULATIONS NEED TO JUSTIFY WHAT YOUR DETAIL SHOWS. |
| 11/22/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/23/2005 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 11/23/2005 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/25/2005 | BETH GRANT | OUT TO CUSTOMER | Completed |