Permit Number: T05CM05124
Parcel: 140420150

Address:
2660 E MEDINA RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05CM05124
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/30/2006 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Approved
09/01/2006 RAUL PALMA BUILDING-COMMERCIAL REVIEW Approv-Cond
09/05/2006 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved 1. The Watts SD-2 dual check valve is not recognized as a backflow prevention assembly because it is not testable (see Section 603.2.4, UPC 2003). Appliances (e.g. coffee brewer, commercial ice maker, etc.) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps require backflow prevention. Reference Sections 602.3, 603.0, and Table 6-2, UPC 2003.
2. The Plumbing connection schedule on sheet K-102 is not legible.
Note: Backflow preventor changed to an approved double-check valve and sheet K-102 replaced, 9/7/06.
09/05/2006 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
09/08/2006 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/10/2006 DELMA ROBEY APPROVAL SHELF Completed
10/10/2006 DELMA ROBEY OUT TO CUSTOMER Completed