Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM05105
Parcel: 117065960

Address:
467 S 3RD AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T05CM05105
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2005 GERRY KOZIOL WWM REVIEW Approved
11/04/2005 MICHAEL ST. PAUL ZONING REVIEW Approved
11/09/2005 NEAL SAUNDERS BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T05cm05105

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen and Pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.
3. Remove all schedules and sheets that do not apply to this plan and/or cross out with black marker (highlighter is not sufficient).

Structural Plan

1. Provide bond beam at top of parapet. Cross sections should match details.
2. Am/6 and Bm/6 - Ledgers and bolts must be sized per R606.10(1). 3x ledger is minimum on masonry construction. Revise plans. Cross sections should match details.
3. Foundation details call for #4 verticals at 32" o/c and 24" o/c. Cross sections note #4 verticals at 48" o/c. Clarify.
4. Cross reference details from roof framing plan.
5. Cross out all details that do not apply.
6. Detail all wood ledger connections at front and rear porch and garage.
7. Provide depth for 20w LPI's.

Plumbing Plan

1. Water line: Provide the total fixture unit demand and maximum developed length. Include size of supply line from meter to house. Table 6.3 and 6.4, 1994 UPC.
2. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type
3. Provide waste venting for master bathroom shower and lavs.

Electrical Plan

1. Where ceiling fans are shown on the plans, provide a note indicating only approved outlet boxes shall be used, per E4001.6.
2. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11.

MODEL ENERGY CODE:

1. Call out on the plan the "R" values of insulation, as well as the "U" values of the windows and doors in compliance with the energy calculations provided. Windows must be low 'E'.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/15/2005 CINDY AGUILAR OUT TO CUSTOMER Completed
11/15/2005 SUE REEVES REJECT SHELF Completed