Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T05CM05080
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or application for exception per DS 2-15.0. |
| 11/21/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/12/2005 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | December 8, 2005 CITY OF TUCSON - FIRST CHECK Tucson Appl. No. P05CM05080 LP2A Job No. 2050161.021 City of Tucson 201 N. Stone Ave. 1st Floor Tucson, AZ 85701 Re: Plan Review: Schulte Duplex – Unit #1 Linhart Petersen Powers Associates (LP2A) has completed a review of the following documents on behalf of the Pima County: 1. Plans: Two (2) sets of plans (21sheets, C0.0 through E1.1) with sheets dated October 4, 2005, by Bright/Kliman Architects. 2. Truss Calculations: None provided. Structural Calculations: None provided. Energy Compliance: One (1) set of Title 24 compliance. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Pima County amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Our comments follow on the attached list. Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, LINHART PETERSEN POWERS ASSOCIATES Tom Haney, Senior Plans Examiner ICC Plans Examiner JTH:lw c:/tucson\2050161-021-pc1 enclosures Re: Stories: One Fire Sprinklers: No Building Area (sq. ft.): 1,844 (livable) 253 (covered porch) A. The following plan review comments are based on the Pima County Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). ARCHITECTURAL COMMENTS: CONVENTIONAL FOUNDATION: Please show required holddowns as specified on lateral design or as required for all alternate braced wall panels, on the foundation plan. IRC Section: R106 Sheet S1.1 ELEVATIONS: Provide height dimensions for roofline, headers, top plate and finished floor. IRC Section: R106 Sheet A2.1 Note dimension that the fireplace chimney must terminate a minimum of two feet above any point of a roof within ten feet measured horizontally. IRC R1001.6 Sheet A2.1 For this coat stucco systems over foam board, note and specify the ICBO Evaluation Report number, system name and manufacturer. Note and specify the vapor barrier used. R106 Sheet A2.1 STRUCTURAL COMMENTS: 1. Rafter must be within the span limitations of IRC Table R802.5.1. Provide engineering for proposed 4 x 12 at 48” o.c. rafters; that the rafters will support the proposed roof-system, ceiling system, live loads and dead loads. IRC Table R802.5.1, Sheet S1.1 2. Provide ICBO Evaluation Report number and manufacturer of all concrete or clay-type tile roofing. IRC Chapter 9, Sheet S1.1 3. Note weights of all plies and coating of built-up roofing. IRC Chapter 9, Sheet A1.2 4. Note and specify the complete roofing system; specify roofing type, grade of materials, underlayment required and method of installation and attachments of roofing materials as required by IRC Chapter 9, Sheet A1.2 5. Fireplace: factory built fireplaces (zero-clearance) shall be listed by an approved listing agency. Specify make and model number and provide approval number of the testing agency. IRC 1004, Sheet A1.1 MECHANICAL, ELECTRICAL AND PLUMBING COMMENTS: 1. Provide combustion air for all liquid and solid fuel burning appliances including size, type and location of openings. IRC Chapter 17, Sheet M1.1 Indicate the location of the T and P relief line from the water heater to the exterior of the building. IRC P2803.6.1, Sheet P1.1 If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F. |
| 12/16/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | Site plan approval required. |
| 12/22/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | Approved site plan is required prior to building plan approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/15/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 02/15/2006 | SUE REEVES | REJECT SHELF | Completed |