Permit Number: T05CM05050
Parcel: 106022280

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T05CM05050
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/06/2005 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: Michael St.Paul
Planner Technician

PROJECT:
T05CM05050
311 West Pastime Road
2nd review
TRANSMITTAL:
December 6, 2005


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. The plan submitted is for an expansion of an existing apartment complex in the R-2 zone. This expansion requires full code compliance with the current Land Use Code. The Development Designator is "K" for multifamily use (LUC Sections 2.3.5.2.A.2 and 3.2.3.1.C).

2. A five-foot (5') pedestrian refuge is required between all structures and all vehicle use areas. This pedestrian refuge must have a sidewalk that is four feet (4') wide and is setback one foot (1') from the parking area access lane (PAAL). The pedestrian refuge must be accessible and provide safe and complete pedestrian circulation from all structures and the street. The pedestrian refuge areas must be provide between the existing buildings and the parking area and driveway, and it also must be provided between the proposed building and the driveway and parking areas (DS 2-02.2.1.A.12 and DS 3-04.2.2.B.1).

3. The minimum width for a two-way PAAL is twenty-four feet (24'). The PAAL width to the west of the two existing buildings and the proposed building is inadequate. Clearly delineate the existing and proposed driveway and parking areas. Also provide dimensions for the parking spaces and the parking bumpers (DS 2-02.2.1.A.12, DS 3-05.2.1.C.1, DS 3-05.2.3.C.2, and LUC Sections 3.3.7.2 and 3.2.8.3).

4. The minimum setback of two feet (2') must be maintained between a PAAL and any wall, screen, fence or other obstruction. Provide a two-foot (2') setback between the PAAL and the fence and property line along the east boundary of the site (DS 2-02.2.1.A.12 DS 3-05.2.2.B.3, and LUC Sec 3.3.7.2 and 3.2.8.3).

5. Please change the parking calculation for the two (2), two (2) bedroom apartments from 1 X 4 = 4 to 2 X 2 = 4 (LUC Sec 3.3.4).

6. Comment 1 is a statement of conditions and subject of this review. Comment 5 is a minor change to the plan. Comments 2, 3 and 4 are subject to an application for variances from the Board of Adjustment.
12/06/2005 MICHAEL ST. PAUL NPPO REVIEW Passed
12/16/2005 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/21/2005 JOSE ORTIZ ENGINEERING REVIEW Approved