Permit Review Detail
Review Status: Active
Review Details: RESUBMITTAL
Permit Number - T05CM04934
Review Name: RESUBMITTAL
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/16/2006 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T05CM04934 3/1/06 3445 S. JESSICA AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. NOTE THE GAS IS TO BE RE-ROUTED AROUND THE ADDITION. 2. NOTE THE ELECTRIC SERVICE ENTRANCE IS REQUIRED TO BE A MINIMUM OF 8' ABOVE THE ROOF. FOUNDATION PLANS: 1. ADD FOOTINGS UNDER THE NEW BEARING MEMBERS. COLUMNS NOTED AS #3 ON PAGE 3 ; 4X6 POSTS NOTED AS #8 ON PAGE 3 ; UNDER THE STAIRS BEARING MEMBERS ; UNDER THE COLUMNS NOTED AS #2 ON PAGE 2. PROVIDE A FOUNDATION PLAN LOCATING THESE FOOTINGS AND PROVIDE A REFERENCE TO THE LOCATION OF THE CROSS SECTION OF THE FOOTING. FLOOR PLANS: 1. INDICATE THE LOCATION OF THE BRACED WALL PANELS. SEE R602.10 . STRUCTURAL PLANS: 1. PROVIDE COMPLETE ROOF AND FLOOR FRAMING PLANS. SHOW SIZE, SPACING AND SPAN OF ALL FRAMING MEMBERS ( RAFTERS AND BEAMS ) 2. ON THE FLOOR FRAMING PLAN, NOTE AND DETAIL DOUBLE JOISTS PARALLEL TO BEARING PARTITIONS, DOUBLE TRIMMERS AND HEADER JOISTS AT FRAMED OPENINGS, FRAMING ANCHORS FOR TAIL JOISTS AND HEADER SUPPORT, AND BRIDGING OR BLOCKING AT THE ENDS AND BEARING POINTS OF THE FLOOR JOISTS. 3. DETAIL ALL SHEAR CONNECTIONS FROM THE FOUNDATION TO THE ROOF PLYWOOD. 4. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES. ELEVATIONS: 1. PROVIDE COMPLETE DRAWINGS OF ALL ELEVATIONS. SHOW BUILDING HEIGHTS. 2. INDICATE ALL MATERIALS USED; STUCCO, CONCRETE BLOCK, GLASS BLOCK, ROOFING SYSTEMS, SIDING, VENEERS, ETC. 3. NOTE AND SPECIFY A COMPLETE ROOFING SYSTEM: ROOFING TYPE, GRADE OF MATERIALS AND METHOD OF INSTALLATION PER R905. 4. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905). SECTIONS - DETAILS - MISC. NOTES: 1. SECTION 1 ; MSTCs AREN'T APPROVED FOR WOOD/MASONRY CONNECTION. 2. PLEASE LOCATE THESE SECTIONS ON THE PLANS. 3. SECTION 3 ; IDENTIFY THE BEARING ELEMENTS AND THE CONNECTIONS. 4. SECTION 3 ; THE 2X6 RAFTER IS OVER SPANNED. 5. SECTION 3 ; PROVIDE THE ROOF SLOPE. 6. SECTION 3 ; IDENTIFY THE ROOF DECK AND THE ROOFING MATERIAL. 7. ELEVATION-1st & 2nd LEVEL ; SAME NOTES AS FOR SECTION 3. 8. ELEVATION-1st&2nd LEVEL ; HOW IS THE RIGHT BEARING ELEMENT SUPPORTED. 9. CROSS-SECTIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLAN AND FRAMING PLANS. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/03/2006 | SUE REEVES | REJECT SHELF | RECEIVED |