Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM04762
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/26/2005 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS for Activity # T05CM04762 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FOUNDATION PLANS: 1. Clarify rebar location with 3" clear from footing bottom for detail D/3. 2. Clarify the wall material and the required anchoring/reinforcement for detail F/3. 3. Identify the anchor bolt size and spacing, R403.1.6 and treated plate, R319.1 for detail G/3. 4. Show all post foundations and base connections. FLOOR PLANS: 1. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture) IRC figure R307.2. 2. Correct the window plan scale sheet 2. STRUCTURAL PLANS: 1. Correct the 6" x 8" undersized beam, sheet 3. 2. The 4" x 8" roof edge member, framing plan 2/3 is not consistent with the 2" x 6" under flashing member, detail C/3. Show compliance with the one-hour fire-resistive requirement (R302.1) by showing fire-retardant-treated wood at the exposed edge, or similar method. ELEVATIONS: 1. Note and specify a complete roofing system: Roofing type, grade of materials and method of installation, rolled R905.5 or metal R905.10. 2. Note and specify all roof slopes appropriate with selected material. 3. Specify veneer anchoring method, backing, vapor barrier and support (ties spaced max 24" o/c horizontally & vertically), R301.2.2.3 & R703.7. Include single course locations. 4. Show 1" air space between sheathing and veneer R703.7.4.2. 5. For thin-coat stucco systems over foam board, note and specify the ICBO evaluation report number, system name and manufacturer, note and specify the vapor barrier, R703.6. SECTIONS - DETAILS - MISC. NOTES: 1. Note and specify the size, spacing and length of anchor bolts for the ledger supporting the existing roof. PLUMBING PLANS: 1. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code. 2. Note and specify all piping materials. 3. Provide the total fixture unit demand for the entire property per 1994 UPC Table 6-3, and determine the supply line diameter from Table 6-4 assuming 46 to 60 psi. The water line diameter from the meter may require upgrading. 4. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute, State Amend. R4-48-104. 5. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. 6. Hose bibs require backflow preventers, UPC 603. 7. Note and specify graywater waste line compliance with UPC Appendix G, State amendment. 8. The graywater system shall not result in any surfacing of the graywater, UPC Appendix G1(a). Correct "gray water to yard" note, detail A/4. MECHANICAL PLANS: 1. Note on plans: Mechanical shall comply with 2003 IRC chapters 12 - 24. 2. Provide a heated air source to all habitable rooms (office), R303.8. ELECTRICAL PLANS: 1. Note on plan that all electrical work shall comply with 2003 IRC chapters 33 - 42. 2. Bathroom receptacles shall be on a separate 20 AMP (not 15 AMP) circuit with no other outlets, E3603.4. 3. Provide the circuit number for the exterior receptacle. 4. Provide a note indicating only approved outlet boxes shall be used for ceiling fans, E4001.6. 5. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11. 6. Smoke alarms are required outside each separate sleeping area R313.1.2. 7. An arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, E3802.11. MODEL ENERGY CODE: 1. Additions greater than 20% of existing square footage of dwelling require compliance with MEC requirements. 2. Provide energy calculations per the 2000 IECC w/ local amendments (climate zone 4B, Pima County < 4000 ft, 2100 HDD) to support selected "R" values of insulation and "U" values of the windows and doors. http://www.energycodes.gov/rescheck/ If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/31/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 10/31/2005 | SUE REEVES | REJECT SHELF | Completed |