Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T05CM04744
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/07/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 10/07/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 10/07/2005 | DAN CASTRO | ZONING | REVIEW | Denied | Zoning may not approve the building plans prior to site plan approval. |
| 10/07/2005 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Sheet A-3 states that power pole is to be replaced by a new pole. Is new pole a whole section or different sections? If separate sections provide details showing how it's being put together, also provide engineering calc's for pole. 2) Provide engineering calc's and details for foundation. 3) Specify the weight of the equipement to be set on the fondation. |
| 10/07/2005 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 10/07/2005 | SREEVES1 | WWM | REVIEW | Passed | no plbg |
| 10/11/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 10/18/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Provide cut sheets for the Factory Pre-Wired Outdoor Equipment Cabinet. Include any listing information. 2. Grounding Electrode Conductors shall be #2, not #4. Reference NEC Table 250.66. 3. Provide Tucson Electric Power Company fault current, and fault calculations as necessary. 4. It does not appear that the 15 KW generator is sufficient to power the 36.5 KVA load. 5. Since the ATS does not switch the grounded conductor, please specify that generator bonding jumper, if any, be removed. Reference NEC 250.4 (5). |
| 10/26/2005 | ALINE TORRES | ZONING-CITY HALL | REVIEW | Denied | special exception required.Application not submitted to DSD as of 10/7/05. No permits to be issued until SE granted. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/01/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 11/01/2005 | SUE REEVES | REJECT SHELF | Completed |