Permit Number: T05CM04590
Parcel: 106101310

Address:
3975 N MILLER AV

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T05CM04590
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2005 DAN CASTRO ZONING HC SITE REVIEW Denied See Zoning Review comments.
10/26/2005 DAN CASTRO ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Heather Thrall Senior Planner FOR: David Rivera Principal Planner


PROJECT: T05CM04590
3975 N. Miller Avenue
Adding Train Caboose Display to Train Museum
Site plan
2nd Review
Transmittal date: October 26, 2005



COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. A striped pedestrian path will not meet minimum requirements for an accessible pedestrian sidewalk. Refer to D.S. 2-08.5.1.C for acceptable composition of sidewalks. In addition, D.S. 2-08.4.1 requires that all sidewalks within a project be physically separated from any vehicular travel lane by means of curbing, grade separation, barriers, railings, or other means, except at crosswalks. The site plan shows the pedestrian path located in the middle of a PAAL. (D.S. 2-02.2.1.A.12)

Per DS 2-02.2.1.12 and ANSI Chapters 4 & 5, handicapped circulation should be provided to the proposed caboose display. Please include handicapped ramps and crosswalks in the modification of the pedestrian access to the caboose display. Note, the maximum slope of handicapped accessible ramps are 1:12. Please provide a typical detail drawing of the handicapped ramps to be provided on the site. Note, to ensure the access areas are installed safely, sidewalks and pedestrian/handicapped access areas may not be located between any motor vehicle parking space and the PAAL providing access to that space, DS 2-08.4.1.F.

2. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 791-4541x1156.


If you have any questions about this transmittal, please call (520) 791-5608.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/26/2005 KMEDINA1 OUT TO CUSTOMER Completed
10/26/2005 KMEDINA1 REJECT SHELF Completed