Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM04276
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/16/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 02/27/2006 | SREEVES1 | NPPO | REVIEW | Needs Review | |
| 02/27/2006 | SREEVES1 | LANDSCAPE | REVIEW | Needs Review | |
| 02/27/2006 | SREEVES1 | ZONING HC SITE | REVIEW | Needs Review | |
| 02/27/2006 | SREEVES1 | ZONING | REVIEW | Needs Review | |
| 02/27/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: February 27, 2006 ACTIVITY NUMBER: T05CM04276 PROJECT NAME: Material Storage PROJECT ADDRESS: 1315 E. Miracle Mile PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN, DRAINAGE REPORT 1. Show the recordation (Book and Page) information for Miracle Mile. It is acknowledged that the parcel (tax code number) has been provided. However the requested information was the recordation (Book and Page) information for Miracle Mile. Show this information on the site plan. 2. Dimensions from street centerline to the existing curb, sidewalk, and utility lines. (See above comment 6). Label dimensions accordingly. This comment has not been addressed from the first review. Provide the requested dimensions from street centerline. DS 2-01.2.1.A.21. 3. Show more spot elevations as pertinent and give Bench Mark based on City of Tucson Datum, including City Field Book and page number. DS 2-02.2.1.A.23. The above comment is from the first review and has not been addressed completely. It is acknowledged the Bench Mark based on City of Tucson Datum, including City Field Book and page number has been added to sheet C1-1. However spot elevations have not been added. It is acknowledged more finish grades have been added to the site plan, which is helpful to determine the direction of drainage after the site has been paved. Per SMDDFM 12.5. Stormwater must be accepted and released from developments essentially at the same locations, and with the same magnitudes, as encountered under natural or existing conditions. Showing existing grades (spot elevations) on the site plan helps determine if the direction of drainage is being changed. Provide spot elevation (existing grades). DRAINAGE REPORT COMMENTS 1. The existing and developed runoff coefficients (0.60 existing and 0.92 developed) used for calculating the 100-yr peak discharge (Q100) are different then the coefficients used (0.32 existing and 0.711 developed) for calculating the retention volume. Provide an explanation on why the same coefficients have not been used when calculating the retention volume or revise the drainage report to use the same coefficients. Stormwater Detention/Retention Manual Section 3.2.2. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/27/2006 | SUE REEVES | OUT TO CUSTOMER | Completed |