Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T05CM04199
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 09/02/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 09/02/2005 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/07/2005 | TERRY STEVENS | ZONING | REVIEW | Denied | 1. Zoning has reviewed the building plans but cannot approve them at this time. Zoning will re-review and approve the building plans on the next submittal providing the stamped and approved site plans are included with the building plan package. |
| 09/08/2005 | JIM EGAN | FIRE | REVIEW | Denied | 1. Minimum 2-hour fire rated exterior wall required for South Wall located less than 5'-0" from property line. Minimum 30-inch parapet required. |
| 09/15/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | Site plan must be approved before the building plan can be approved. |
| 09/20/2005 | SEPTIC APPROVAL | WWM | REVIEW | Approved | |
| 09/23/2005 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Denied | City of Tucson, Development Services BUILDING AND STRUCTURAL COMMENTS 9/26/05 1) Provide a 2 hour rated wall at south side of building with a 30" parapet. Show detail of rated wall. 2) Show location of existing bathrooms, including physically handicpped unit. 3) Specify the wind force that the structure is designed for. 4) How is the wind force resisted by the structure in the longitudinal direction? |
| 09/29/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Air Compressor listed as 230V on Electrical, but is powered at 208V according to the panel schedule. Please clarify. 2. Air compressor (2400) (2) / 208 = 23.1 A. This does not correspond to a 5 HP motor in either the 208V or 230V class, according to NEC Table 430.148. 3. Demonstrate compliance with 2000 IECC. 4. Address the grounding requirements of NEC 250.32 for Two or More Buildings Supplied From a Common Service. 5. Provide fault current at electrical service. 6. Provide fault calculations for AFC at New Panel S. 7. Provide fault current rating of New Panel S. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/08/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 11/08/2005 | SUE REEVES | REJECT SHELF | Completed |