Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05CM04073
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/04/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 08/09/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or application for exception per DS 2-15.0. |
| 08/09/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit a separate landscape plan per DS 2-07.0 2. Street landscape borders shall be a minimum of ten (10) feet wide as measured from the street property line. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by Sec. 2.8.3.4. Dimension landscape borders accordingly 3. Fifty (50) percent or more of the area of the street landscape border must be covered with shrubs or vegetative ground cover. The required ground coverage must be achieved within two (2) years from the date of planting. (20) Percent of the required landscaping is to be five- (5) gallon container size or larger. 4. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage on the landscape plan per DS 2-07.2.2.2.g. 5. Landscape border(s) along parking lot where plants are susceptible to injury by vehicular traffic must be protected by appropriate means, such as curbs, bollards, or low walls per LUC 3.7.2.3.B. Indicate protection on landscape plans. 6. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. 7. Submit NPPO plan or application for exception per DS 2-15.0. 8. Additional comments may apply |
| 08/26/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Approved | |
| 08/26/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. List the proposed building height. (D.S. 2-02.2.1.A.6) 2. The gross floor area of the proposed building is listed as 580.50 SF on the drawing and 540 SF under the zoning information and parking calculation. In addition, the dimensions of the building 21.33 feet by 21.40 feet total 456.46 SF. Revise to be consistent. (D.S. 2-02.2.1.A.6) 3. Label and dimension existing and future sight visibility triangles. (D.S. 2-02.2.1.A.10) 4. If applicable, provide the location, type, size, and height of existing and/or proposed free standing sign, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.1.A.13) (D.S. 2-02.2.1.A.25) 5. Label and dimension existing and future MS&R right-of-way and curb location for Golf Links Road. (D.S. 2-02.2.1.A.19, and .21) 6. If applicable, all existing and proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 7. Indicate refuse container location, size, and access thereto fully dimensioned. (D.S. 2-02.2.1.A.32) 8. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
| 08/31/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Paul Nzomo DATE: September 1, 2005 Coronado Engineering & Delvelopment, Inc. 1010 N. Finance Center Drive, Ste. 200 Tucson, Arizona 85705 SUBJECT: Lot 5 of "Glyn Circle", 8737 E. Golf Links Road Site Plan T05CM04073 (First Review) T14S, R15E, Section 22 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. Add note: All grading shall conform to City of Tucson Development Standards 11.0. 3. Complete the Basis of Bearings. 4. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 5. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 6. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 7. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. Show the maximum slope of the sidewalk from the proposed building to Golf Links. 8. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 9. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 10. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 11. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22. 12. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 13. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 14. Show Site plan number on all sheets per D.S. 2-02.2.1.29. 15. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Show detail of refuse container. 16. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 17. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. Drainage Statement: 1. The Drainage Statement has been accepted by engineering. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/ 8737 E. Golf Links Rd Site |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/06/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |