Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T05CM03891
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2005 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS for Activity # T05CM03891 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. All detail references shall be consistent on each plan or elevation: Plan reference on A-1 to detail 3/A-1 is to the detail labeled #1. Plan reference on A-1 to section 2/S-2 is not shown at the correct location. FOUNDATION PLANS: 1. Note on S-1 that anchor-bolts shall have a minimum 7" embedment into concrete or masonry. Maximum spacing 6' O.C. and within 12" of each end of sill plate, R403.1.6. 2. Correct the inconsistent footing width shown at 2/S-1 and enlarged section S-2. 3. Show or note a 6" minimum separation of exterior posts above finished grade, R319.1.4. FLOOR PLANS: 1. Appliances installed in garages shall be mounted on platforms at least 18" above the floor, M1307.3. STRUCTURAL PLANS: 1. Specify lateral support of trusses. 2. Show details for critical non-bearing conditions (floor and rafter/joist connection). 3. Provide minimum openings of 22" by 30" for ventilation into over-framed areas (>30 S.F.). 4. Completely detail all connections for over-framing and ledgers. ELEVATIONS: 1. Calculate of attic ventilation area using the correct attic area in compliance with R806.2. Note size and location of all vents needed to comply. SECTIONS - DETAILS - MISC. NOTES: 1. Detail the garage door steel-beam connection to support structure. 2. Note if the existing garage load-bearing wall has appropriate lintels. 3. Clarify which walls of the workshop/garage are to be furred-out (section 1/S-3) on a plan view. 4. Ceiling gypsum board shall be either 5/8" or ½" sag resistant when applied to 24" o.c. framing, IRC table R702.3.5 footnote d. 5. Show a minimum 1" vent clearance between ceiling insulation and roof sheathing if insulation is attached to truss bottom cord and rafter venting is used, R806.3. This may be accomplished w/ baffles. PLUMBING PLANS: 1. Correct the fixture unit schedule showing three P-1 and P-2 units in the plan column. This increases the total fixture unit demand to 33. 2. The 1994 UPC Table 6-4 indicates a total fixture unit demand of 33 with 133' of TDL requires the supply line diameter of 1". Correct note #7, and show the installation of an upgraded water service line from the meter to the master bathroom. 3. Hose bibs require backflow preventers UPC 603. MECHANICAL PLANS: 1. Show bathroom exhaust fan CFM rating R303.3 and M1506. 2. Correct the return air duct size for ACU-01. ELECTRICAL PLANS: 1. Provide a ground electrode on the service detail for the sub-panel, R3507.3. 2. Show locations of smoke detectors in the master bedroom, R313. Correct the wall and ceiling installation dimensions at note #16. 3. An arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, R3802.11. 4. Correct the water heater circuit numbers for the wash room unit #16/18-A and the garage unit #10/12-B. If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/31/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 08/31/2005 | SUE REEVES | REJECT SHELF | Completed |