Permit Number: T05CM03820
Parcel: 13323343B

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T05CM03820
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2006 HEATHER THRALL ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Heather Thrall, Senior Planner
PROJECT: T05CM03820, 7480 E. Speedway Blvd., New Apartment Complex, 5 units
Site plan 4th Review
Transmittal date: November 15, 2006

COMMENTS: Please resubmit revised drawings with a response letter stating how all Zoning Review Section comments were addressed. OR CALL FOR APPOINTMENT


Staff has approved handicapped accessibility, and will stamp the plan with the handicapped parking approval stamp when the site plan can be approved for zoning.

1. (PER LAST REVIEW). Please ensure all typeface on the site plan is revised to a minimum of 12 point, to ensure records can be kept efficiently.
RESPONSE: The type size was increased in several areas of the plan, thank you, however all areas of the site plan - all numbers, letters, details etc. must be 12 point minimum and several numbers and details still are too small to microfilm.

2. (PER LAST REVIEW.). Remove the street cross section
RESPONSE: I see the cross-section now refers to the driveway, which is a very helpful change, thank you. I need simple changes on the cross-section please:
A) remove reference to a parking lane in front of the buildings and show as travel lane.
B) Change the travel lane dimension to 24 feet wide
C) Change the wedge curb against the sidewalk to a vertical curb
D) Enlarge the type size for microfilming purposes please

3. (PER LAST REVIEW.) Per DS 2-02.2.2.A.3,
FOR LOT COVERAGE/LOT LINES/LOT SIZE; CORRECT THE FOLLOWING
A) Pressyc Lane is not included in lot area for this project
B) revise lot lot dimensions for this project - 161.45 x 152.75
C) revise lot size for this project to 24,661 sf (removing Pressyc Lane as part of lot)
D) revise gross lot area note to read .56 acres
E) show lot line on east side of Pressyc (the west property line of this site)
F) provide note "O-3 zone allows maximum 22 units an acre & 75% lot coverage"
G) provide note "proposed number of units is 5 on .56 acres"
H) list building area square footage & paved area square footage & provide total together in square footage. Divide that total by 24,661 to obtain percent lot coverage (will be a decimal number (example .60 or 60%)

4. Please note, depending upon responses provided, further review comments may be forthcoming. Should you have any questions regarding this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 520-791-4541x1156.

NOTE: I am willing to meet with you to go over the requested corrections. Just call or email at your convenience and I'll advise of available appointment times. Thank you!
11/21/2006 HEATHER THRALL ZONING HC SITE REVIEW Approved
11/21/2006 DROBEY1 LANDSCAPE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/21/2006 DELMA ROBEY APPROVAL SHELF Completed
11/21/2006 DELMA ROBEY OUT TO CUSTOMER Completed
11/21/2006 DELMA ROBEY REJECT SHELF Completed