08/10/2005 JIM EGAN FIRE REVIEW Denied Minimum 2-hour fire rated exterior wall required adjacent to south property line. No openings permitted.
08/17/2005 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Add the legal description of the property. (D.S. 2-02.2.1.A.2)

2. Add project address. (D.S. 2-02.2.1.A.3)

3. Dimension the building setback from the back of future curb along 12th Avenue. Per LUC 3.2.6.5.B.1, a minimum 22 foot setback is required. (D.S. 2-02.2.1.A.7)

4. Provide a disabled parking space for the new building. Add a detail for the disabled parking space, access aisle, and ramp. Accessible parking space shall be located on the shortest accessible route of travel from adjacent parking to an accessible building entrance. (2003 IBC Section 1106.6) (ICC/ANSI A117.1-2003) (D.S. 2-02.2.1.A.8)

5. Two (2) Class 2 bicycle parking spaces shall be provided for new building. Indicate the location and number and class type provided on the plan. Provide a fully dimensioned detail for the bicycle parking facility. (D.S. 2-02.2.1.A.9) (D.S. 2-09)

6. Label and dimension existing and future sight visibility triangles. (D.S. 2-02.2.1.A.10)

7. Provide a copy of the recorded vehicle and pedestrian cross access agreement.

8. If applicable, provide a detail of existing and or proposed free standing signage, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.2.1.A.13)

9. Where is the loading zone for the new building. Indicate location and provide dimensions. If the loading zone is existing and located in the shopping center indicate as such. If loading zone is too far from the new building, a loading zone will be required nearby. Provide a loading zone calculation. (D.S. 2-02.2.1.A.14) (D.S. 2-02.2.2.A.5_(LUC 3.4.5)

10. Dimension existing and future right-of-way and curb along 12th Avenue. (D.S. 2-02.2.1.A.19)

11. If applicable, all existing and proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20)

12. Indicate location of refuse container. (D.S. 2-02.2.1.A.32)

13. Provide FAR calculation (maximum allowed and proposed). (D.S. 2-02.2.2.A.3)

14. The new building must be connected to the rest of the shopping center through a minimum four (4) foot on-site sidewalk. (D.S. 2-08)


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person.
08/18/2005 DAN CASTRO ZONING HC SITE REVIEW Denied Provide a disabled parking space for the new building. Add a detail for the disabled parking space, access aisle, and ramp. Accessible parking space shall be located on the shortest accessible route of travel from adjacent parking to an accessible building entrance. (2003 IBC Section 1106.6) (ICC/ANSI A117.1-2003) (D.S. 2-02.2.1.A.8)
08/24/2005 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit a separate landscape plan for expansion area per DS 2-07.0

2. Street landscape borders shall be a minimum of ten (10) feet wide as measured from the street property line. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by Sec. 2.8.3.4. Dimension landscape borders accordingly

3. Fifty (50) percent or more of the area of the street landscape border must be covered with shrubs or vegetative ground cover. The required ground coverage must be achieved within two (2) years from the date of planting. (20) Percent of the required landscaping is to be five- (5) gallon container size or larger.

4. The planting plan and layout calculations will include location, sizes, and name of existing vegetation to remain in place per DS 2-07.2.2.A.1.e

5. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage on the landscape plan per DS 2-07.2.2.2.g.

Additional comments may apply
08/25/2005 ANDREW CONNOR NPPO REVIEW Approved Exception
09/03/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: September 3, 2005
ACTIVITY NUMBER: T05CM03728
PROJECT NAME: Volk Company
PROJECT ADDRESS: 6445 South 12th Avenue
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Add Lot dmiensions to the proposed development. DS 2-02.2.1.A.5.

2. Add the project address to the site plan. DS 2-02.2.1.A.3.

3. Add existing and future sight visibility triangles for all ingress/egress locations. DS 2-02.2.1.A10.

4. Pedestrian circulation must clearly be identified. The new building must have pedestrian circulation to the existing shopping center. The new structure must connect to the existing shopping center. DS 2-02.2.1.A.12., DS 2-08.

5. Show existing drainage patterns, proposed finish floor elevation(s), and finish grades. DS 2-02.2.1.A.16.

6. Include on the site plan estimated cut and fill quantities. If cut and fill quantities equal zero, please note on the plan. DS 2-02.2.1.A.17.

7. Dimension from street centerline the existing and future right of way (ROW) for Valcencia Rd. and 12 the Ave. Indicate book and page for each street. DS 2-02.2.1.A.19.

8. Dimension from street centerline the existing and future curb and sidewalk. DS 2-02.2.1.A.21.

9. Show existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. DS 2-02.2.1.A.23.

10. Indicate on the site plan refuse container location, size, and access thereto fully dimensioned.