Permit Number: T05CM03651
Parcel: 110073540

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T05CM03651
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/30/2005 ANDREW CONNOR NPPO REVIEW Denied Submit NPPO plan or application for exception per DS 2-15.0.
10/13/2005 GERRY KOZIOL WWM REVIEW Denied NEED 8TH FLOOR CREDIT EVALUATION FOR DEMO BUILDING
10/14/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied Approved site plan required prior to building plan approval.
10/21/2005 DAN CASTRO ZONING REVIEW Denied Building plans may not be approved prior to site plan approval and structural review approval of building plans.
10/25/2005 NEAL SAUNDERS BUILDING-RESIDENTIAL REVIEW Denied Plan Review for T05CM03651 and 3652

1. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2.

2. Provide 1-hour firewall per R317 between units. Reference table 720.1 (2) # 13-1.1, 2003 IBC for proper 1-hour firewall construction OR justify chosen construction as 1-hour.

3. How will 1-hour rating of separation wall be maintained with plumbing penetrations per R317.3. Detail penetration firestop or reconfigure plumbing.

4. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute.

5. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code.

6. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24.

7. Provide arc-fault protection for all outlets in bedrooms per E3802.11.

8. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply.

MODEL ENERGY CODE:

2. Provide energy calculations per the 2000 IECC and comply with IRC chapter 11 or 'Rescheck' (www.energycodes.gov/rescheck/).
3. Call out on the plan the "R" values of insulation, as well as the "U" values of the windows and doors in compliance with the energy calculations provided. Windows must be low 'E'.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/26/2005 JMORALE1 OUT TO CUSTOMER Completed
10/26/2005 JMORALE1 REJECT SHELF Completed