Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T05CM03577
Parcel: 133350700

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05CM03577
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/21/2005 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS for Activity # T05CM03577

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All corrections and revisions shall be made on the original tracings and two new sets of drawings shall be returned along with all redline prints. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

FLOOR PLANS:

1. Change all 2000 IRC references to 2003, sheets #3 & 4. Same for the IBC references.
2. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture) and has a clear space in front not less than 21" per figure R307.2.
3. All exterior doors require a landing or floor at the exterior. Landings must be at least as wide as the doors they serve and 36" in the direction of travel per R311.4.3.

ELEVATIONS:

1. Provide the stucco system ICBO evaluation report number, system name and manufacturer referenced on note #1, sheet 3.

SECTIONS - DETAILS - MISC. NOTES:

1. Clarify double keynote references #1 & 4 on the Section detail, sheet #3.
2. Projections shall not extend to a point closer than 2 feet from the property line, and when extending into the 3 foot fire separation distance shall have not less than one-hour fire-resistive construction on the underside. Make corrections in compliance with R302.1.

ELECTRICAL PLANS:

1. An arc-fault circuit interrupter shall protect bedroom outlets R3802.11.
2. Indicate the location of all air conditioning and heating units, air handlers, compressors, and disconnects.

If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112.
07/29/2005 MICHAEL ST. PAUL ZONING REVIEW Denied A LDO approval is required and is in review.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/02/2005 KMEDINA1 OUT TO CUSTOMER Completed